Relationship between head-to-body delivery interval in shoulder dystocia and neonatal depression.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lerner Henry, Durlacher Katherine, Smith Samuel, Hamilton Emily
Аннотация
OBJECTIVE: To evaluate the relationship between the head-to-body delivery interval in shoulder dystocia, persistent brachial plexus injury, and neonatal depression.
METHODS: We compared the head-to-body delivery intervals in 127 cases of uncomplicated shoulder dystocia-identified using medical record coding and verified by chart review in a university--affiliated community hospital--with a series of 55 medical-legal cases of shoulder dystocia with persistent brachial plexus injury, 14 of which included neonatal depression. Neonatal depression was defined as the presence of any of the following: fetal demise, cardiopulmonary resuscitation, intubation, umbilical artery pH lower than 7.00, or 5-minute Apgar score of 5 or lower.
RESULTS: In the uncomplicated shoulder dystocia group, the median head-to-body delivery interval was 1.0 minute (interquartile range 0.5-1.0). The median for neonates with persistent brachial plexus injury and no depression was 2.0 minutes (interquartile range 1.0-4.0). For those with both persistent brachial plexus injury and neonatal depression, the median was significantly longer at 5.3 minutes (interquartile range 3.9-13.3), P<.001.
CONCLUSION: Neonates born with persistent brachial plexus injury and neonatal depression after shoulder dystocia had longer head-to-body delivery intervals than those with uncomplicated shoulder dystocia or shoulder dystocia with persistent brachial plexus injury without depression. By 4 minutes, all of the neonates with uncomplicated shoulder dystocia were born. Conversely, the majority of neonates with depression-57%-had head-to-body delivery intervals greater than 4 minutes. Such information offers guidance to clinicians caught between the admonition to apply only gentle force when utilizing maneuvers to accomplish a shoulder dystocia delivery and the countervailing need to achieve delivery within a critical time frame to prevent hypoxic injury.
LEVEL OF EVIDENCE: III.
METHODS: We compared the head-to-body delivery intervals in 127 cases of uncomplicated shoulder dystocia-identified using medical record coding and verified by chart review in a university--affiliated community hospital--with a series of 55 medical-legal cases of shoulder dystocia with persistent brachial plexus injury, 14 of which included neonatal depression. Neonatal depression was defined as the presence of any of the following: fetal demise, cardiopulmonary resuscitation, intubation, umbilical artery pH lower than 7.00, or 5-minute Apgar score of 5 or lower.
RESULTS: In the uncomplicated shoulder dystocia group, the median head-to-body delivery interval was 1.0 minute (interquartile range 0.5-1.0). The median for neonates with persistent brachial plexus injury and no depression was 2.0 minutes (interquartile range 1.0-4.0). For those with both persistent brachial plexus injury and neonatal depression, the median was significantly longer at 5.3 minutes (interquartile range 3.9-13.3), P<.001.
CONCLUSION: Neonates born with persistent brachial plexus injury and neonatal depression after shoulder dystocia had longer head-to-body delivery intervals than those with uncomplicated shoulder dystocia or shoulder dystocia with persistent brachial plexus injury without depression. By 4 minutes, all of the neonates with uncomplicated shoulder dystocia were born. Conversely, the majority of neonates with depression-57%-had head-to-body delivery intervals greater than 4 minutes. Such information offers guidance to clinicians caught between the admonition to apply only gentle force when utilizing maneuvers to accomplish a shoulder dystocia delivery and the countervailing need to achieve delivery within a critical time frame to prevent hypoxic injury.
LEVEL OF EVIDENCE: III.