MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0954411919891885

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2019

Evaluation of bone excision effects on a human skull model - I: Mechanical testing and digital image correlation.

Franceskides Constantinos, Leger Thibault, Horsfall Ian, Tozzi Gianluca, Gibson Michael, Zioupos Peter

СтатьяПеревод в очереди

Аннотация

The mechanisms of skull impact loading may change following surgical interventions such as the removal of bone lesions, but little is known about the consequences in the event of subsequent head trauma. We, therefore, prepared acrylonitrile butadiene styrene human skull models based on clinical computed tomography skull data using a three-dimensional printer. Six replicate physical skull models were tested, three with bone excisions and three without. A drop tower was used to simulate the impact sustained by falling backwards onto the occipital lobe region. The impacts were recorded with a high-speed camera, and the occipital strain response was determined by digital image correlation. Although the hole affected neither the magnitude nor the sequence of the fracture pattern, the digital image correlation analysis highlighted an increase in strain around the excised area (0.45%-16.4% of the principal strain). Our approach provides a novel method that could improve the quality of life for patients on many fronts, including protection against trauma, surgical advice, post-operative care, advice in litigation cases, as well as facilitating general biomechanical research in the area of trauma injuries.

Для цитирования: Franceskides Constantinos, Leger Thibault, Horsfall Ian, Tozzi Gianluca, Gibson Michael, Zioupos Peter. Evaluation of bone excision effects on a human skull model - I: Mechanical testing and digital image correlation.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2019. DOI: 10.1177/0954411919891885.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.