QUESTION: Do clinical tests accurately diagnose rotator cuff pathology?

DESIGN

A systematic review of investigations into the diagnostic accuracy of clinical tests for rotator cuff pathology.

PARTICIPANTS

People with shoulder pain who underwent clinical testing in order to diagnose rotator cuff pathology.

OUTCOME MEASURES: The diagnostic accuracy of clinical tests was determined using likelihood ratios.

RESULTS

Thirteen studies met the inclusion criteria. The 13 studies evaluated 14 clinical tests in 89 separate evaluations of diagnostic accuracy. Only one evaluation, palpation for supraspinatus ruptures, resulted in significant positive and negative likelihood ratios. Eight of the 89 evaluations resulted in either significant positive or negative likelihood ratios. However, none of these eight positive or negative likelihood ratios were found in other studies. Of the 89 evaluations of clinical tests 71 (80%) did not result in either significant positive or negative likelihood ratio evaluations across different studies.

CONCLUSION

Overall, most tests for rotator cuff pathology were inaccurate and cannot be recommended for clinical use. At best, suspicion of a rotator cuff tear may be heightened by a positive palpation, combined Hawkins/painful arc/infraspinatus test, Napoleon test, lift-off test, belly-press test, or drop-arm test, and it may be reduced by a negative palpation, empty can test or Hawkins-Kennedy test.

Для цитирования: Hughes Phillip C, Taylor Nicholas F, Green Rod A. Most clinical tests cannot accurately diagnose rotator cuff pathology: a systematic review.. The Australian journal of physiotherapy. 2008. DOI: 10.1016/s0004-9514(08)70022-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.