MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17085381231158440

Медицинская библиотека · Vascular · 2023

Treatment of stent rupture after endovascular treatment of superior mesenteric aneurysm with open surgery.

He Yiwei, Zhang Jun, Li Gangzhi, Zhou Haining

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

The progress of visceral artery aneurysms (VAAs) after the endovascular repair of artery aneurysms is often accompanies by the potential risks of stent fracture. The clinical reported cases of VAAs stent fractures with stent displacement were extremely rare but severe complication, particularly for the superior mesenteric artery aneurysm (SMAA).

METHOD: We here reported a 62-year-old female patient with recurrent symptoms of SMAA 2 years after the successful endovascular repair using coil embolization and two partial overlapping stent-grafts in SMAA. The open surgery was performed instead of secondary endovascular intervention.

RESULT AND

CONCLUSION

The patient experienced a good recovery. As one of the complications after endovascular repair, stent fracture maybe more dangerous than SMAA itself, the stent fracture after endovascular repair treated by open surgery with satisfactory results is alternative and feasible.

Для цитирования: He Yiwei, Zhang Jun, Li Gangzhi, Zhou Haining. Treatment of stent rupture after endovascular treatment of superior mesenteric aneurysm with open surgery.. Vascular. 2023. DOI: 10.1177/17085381231158440.

Предметные рубрики MeSH