Repair of femoral fractures in calves via external skeletal fixator with intramedullary pin tie-in.

Hilliard Rachel L, Livesey Michael A, De Gasperi Diego

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe the success rate and associated complications of external skeletal fixator/intramedullary pin tie-in for calf femoral fracture fixation.

STUDY

DESIGN

Clinical retrospective.

ANIMALS: Ten calves, less than 30 days old, with diaphyseal/metaphyseal femoral fractures.

METHODS

Medical records were reviewed from the University of Wisconsin from 2000 to 2020. Fractures were repaired using open reduction and fixation. An intramedullary Steinman pin was placed, exiting near the greater trochanter, and utilized for fracture reduction. Bicortical transfixation pins were placed distal and proximal to the fracture site. Poly(methyl methacrylate) (PMMA)-filled tubing connected the transfixation pins and proximal intramedullary pin, creating a Type 1a external skeletal fixator (ESF) tie-in. Follow up was obtained via medical records and phone interviews.

RESULTS

Short-term survival rate was 7/10 (70%). Postanesthetic death occurred once. Postoperative complications occurred in all remaining cases. The most common findings were transfixation pin tract lucency and lameness (6/9 cases), implant dysfunction (5/9 cases), and infection (4/9 cases). Three of five cases with long-term follow up survived; all went on to productive careers.

CONCLUSION

Although patients were prone to postoperative complications, short-term survival was comparable to previous reports.

CLINICAL SIGNIFICANCE: The external skeletal fixator/intramedullary (ESF/IM) pin tie-in is less expensive and offers comparable success rates to other methods, providing a lower cost option for calf femoral fracture repair.

Для цитирования: Hilliard Rachel L, Livesey Michael A, De Gasperi Diego. Repair of femoral fractures in calves via external skeletal fixator with intramedullary pin tie-in.. Veterinary surgery : VS. 2023. DOI: 10.1111/vsu.13996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.