MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jac/dky569

Медицинская библиотека · The Journal of antimicrobial chemotherapy · 2019

Temocillin breakpoints in pyelonephritis: evaluation in a murine model due to ESBL-producing Escherichia coli clinical isolates.

Alexandre Kévin, Soares Anaïs, Chau Françoise, Fantin Bruno, Caron François, Etienne Manuel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Due to a spectrum restricted to Enterobacteriaceae and stability against ESBL and AmpC enzymes, temocillin is of major interest for the treatment of pyelonephritis. But there are still uncertainties about the optimal regimen and clinical breakpoints.

OBJECTIVES

To study in a murine model of pyelonephritis the activity of temocillin against Escherichia coli isolates with different MICs in order to evaluate clinical breakpoints.

METHODS

Four clinical uropathogenic E. coli isolates with temocillin MICs of 8 mg/L (Ec8), 16 mg/L (Ec16), 32 mg/L (Ec32) and 64 mg/L (Ec64) were evaluated. Antibiotic 24 h T>MIC achieved in humans was reproduced in mice with either intravenous temocillin (2 g q12h or 2 g q8h) or intravenous imipenem (1 g q8h). Efficacy was assessed by bacterial count in kidneys.

RESULTS

Compared with controls, temocillin at 2 g q12h was highly efficient against Ec8 (-3.32 log10 cfu/g and negative cultures in 93% of mice; P < 0.001); imipenem gave similar results. Temocillin at 2 g q12h also induced high reduction of bacterial count against Ec16 (-2.92 log10 cfu/g; P < 0.001), albeit cultures were negative in only 48% of mice. In contrast, no significant effect was observed in mice infected by Ec32 (-0.01 log10 cfu/g; P = 0.981) or Ec64 (-0.55 log10 cfu/g; P = 0.523). Even temocillin at 2 g q8h failed to control Ec32 infection (-1.55 log10 cfu/g; P = 0.197).

CONCLUSIONS

This model suggests a clinical breakpoint up to 16 mg/L for non-severe pyelonephritis treated with temocillin at 2 g q12h, a value consistent with the few previous available data.

Для цитирования: Alexandre Kévin, Soares Anaïs, Chau Françoise, Fantin Bruno, Caron François, Etienne Manuel. Temocillin breakpoints in pyelonephritis: evaluation in a murine model due to ESBL-producing Escherichia coli clinical isolates.. The Journal of antimicrobial chemotherapy. 2019. DOI: 10.1093/jac/dky569.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.