MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon2000104241

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2000

Reduction of carotid arterial blood flow in ventricular septal defect associated with severe congestive heart failure.

Kojo M, Yamada K, Akiyoshi S, Maeda M, Sato K, Izumi T

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

After diagnosing abnormality of cardiac and carotid-cerebral circulation in an infant with isolated ventricular septal defect (VSD) associated with severe congestive heart failure, the authors measured the carotid arterial blood flow volume (CABF). At 3 months, the patient was not thriving and had dyspnea because of severe congestive heart failure. The authors measured the VSD size/body surface area (BSA) ratio relative to the predicted value of the left ventricular end-diastolic dimension (%LVEDd), left-to-right shunt ratio (Qp/Qs), and the small stroke volume (SV)/BSA using echocardiography and cardiac catheterization. The mean, maximum, and minimum CABF (mean CABF, maxCABF, and minCABF) among R-R intervals on electrocardiogram were measured by Doppler flowmetry in this patient and 5 healthy age-matched control children. The patient had a large VSD size/BSA ratio (37.9 mm/m2), %LVEDd (164%), and Qp/Qs (3.8), and a small SV/BSA ratio (18 mL/m2). The mean CABF, maxCABF, and minCABF were significantly lower than those of control children (VSD patient vs. controls; 2.7 +/- 0.4 vs. 4.5 +/- 0.6, 6.1 +/- 0.9 vs. 12.0 +/- 2.1, 1.2 +/- 0.2 vs. 1.7 +/- 0.4 mL/sec (mean +/- S.D.)), respectively (p < 0.01). The authors' results showed abnormal cardiac and carotid-cerebral circulation in an infant with large VSD associated with severe congestive heart failure.

Для цитирования: Kojo M, Yamada K, Akiyoshi S, Maeda M, Sato K, Izumi T. Reduction of carotid arterial blood flow in ventricular septal defect associated with severe congestive heart failure.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2000. DOI: 10.1111/jon2000104241.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.