m+Medelevator.RU
← Поиск публикаций
Perfusion · 2024

A clinical comparison of glycol and water-based heater-cooler systems for cardiopulmonary bypass.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ohlrich Kelly, Kwon Jennie, Hill Morgan A, Ayala McKenzie, Stone Amber, Bruner Samantha, Pollard Melissa, Dell'Aiera Laura, Fitzgerald David, Kilic Arman

Аннотация

IntroductionWhile newer heater-cooler technologies using ethylene glycol-based (GB) solutions during cardiothoracic surgery have become commercially available, there is a paucity of clinical data describing their effectiveness during cardiopulmonary bypass (CPB) support. This analysis aimed to compare clinical characteristics and procedural outcomes using water-based (WB) and GB heater-cooler systems.MethodsA retrospective analysis was performed on consecutive adult patients undergoing CPB from June to October 2022 comparing WB or GB groups. The primary outcome was a composite of operative death or major morbidity. Secondary endpoints included transfusion requirements on CPB, patient cooling and warming rates, and vasoactive-inotropic scores (VIS) at case completion. P-control charts were used to monitor the weekly incidence of the composite outcome. A sub-analysis was performed to evaluate the primary outcome for cardiac surgery cases indexed by the Society of Thoracic Surgeons (STS).ResultsThere were 167 patients included for analysis; 87 (52.1%) underwent CPB with a WB system and 80 (47.9%) with a GB system. GB procedure subjects were younger (p = .01), experienced longer CPB times (p = .034), and were more likely to receive thoracic transplant or aortic surgery (p = 0.015). The composite outcome of operative mortality or major morbidity occurred in 29.9% and 24% of the WB and GB groups, respectively (p = .372). P-control charts indicated a weekly mean incidence of 30% during WB practice, which decreased to 24% with GB practice. Among 106 STS-indexed cardiac surgery cases, mean composite outcome incidence decreased from 19% to 6% following our GB transition. Additionally, cooling, and warming rates indexed to patient BSA and VIS at case completion were not significantly different.ConclusionOur analysis demonstrated a safe transition from WB to GB heater-cooler technologies in our practice. This early analysis suggests that GB heater coolers may be safely adopted to mitigate the risks of nontuberculous mycobacterium infections for cardiac surgical patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты