Reliability of distal tibio-fibular syndesmotic instability measurements using weightbearing and non-weightbearing cone-beam CT.

Osgood Greg M, Shakoor Delaram, Orapin Jakrapong, Qin Jianzhong, Khodarahmi Iman, Thawait Gaurav K, Ficke James R, Schon Lew C, Demehri Shadpour

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To investigate the reliability and reproducibility of syndesmosis measurements on weightbearing (WB) cone-beam computed tomography (CBCT) images and compare them with measurements obtained using non-weightbearing (NWB) images.

METHODS

In this IRB-approved, retrospective study of 5 men and 9 women with prior ankle injuries, simultaneous WB and NWB CBCT scans were taken. A set of 21 syndesmosis measurements using WB and NWB images were performed by 3 independent observers. Pearson/Spearman correlation and intra-class correlation (ICC) were used to assess intra- and inter-observer reliability, respectively.

RESULTS

We observed substantial to perfect intra-observer reliability (ICC=0.72-0.99) in 20 measurements. Moderate to perfect agreement (ICC=0.45-0.97) between observers was noted in 19 measurements.

CONCLUSION

Measurements evaluating the distance between tibia and fibula in the axial plane 10mm above the plafond had high intra- and inter-observer reliability. Mean posterior tibio-fibular distance, diastasis, and angular measurement were significantly different between WB and NWB images.

Для цитирования: Osgood Greg M, Shakoor Delaram, Orapin Jakrapong, Qin Jianzhong, Khodarahmi Iman, Thawait Gaurav K, Ficke James R, Schon Lew C, Demehri Shadpour. Reliability of distal tibio-fibular syndesmotic instability measurements using weightbearing and non-weightbearing cone-beam CT.. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2018. DOI: 10.1016/j.fas.2018.10.003.