MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anpedi.2010.12.009

Медицинская библиотека · Anales de pediatria (Barcelona, Spain : 2003) · 2011

[Usefulness of electrocardiographic screening in a neonatal population].

Cruz Cañete M, Rus Mansilla C, Gómez Lara A, Gavilán Expósito M L, Calleja Cabezas P, Gavilán Pérez M

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Congenital long QT syndrome is a rare disease, but is responsible for nearly 10% of Sudden Infant Death Syndrome. It is characterized by an abnormal prolonged QT interval in the basal electrocardiogram (ECG) with life-threatening arrhythmias which occur in previously asymptomatic patients and are preventable with an appropriate treatment.

AIMS: The impact of introducing ECG-screening in newborns is studied and main ECG-measurements are described in our population.

MATERIAL AND

METHODS

Twelve-lead ECG was carried out.

MEASUREMENTS: RR, PR and QT interval, heart rate corrected QT interval, R wave voltage in V1, AVR and AVL, Q wave in I and AVL, P amplitude and voltage, right bundle branch block and ST elevation (Brugada pattern) and delta wave. It was considered pathological: QTc >0.44 or <0.30 seconds; R >12 in V1 and >8mm in AVR; R >7.5mm in AVL; Q >25% QRS in I and AVL; Brugada pattern; delta wave.

RESULTS

A total of 1061 healthy children were born in our hospital between 29 May 2007 and 12 December 2008, of which 50.3% were males. An ECG was performed on 1006 (94.8%). Five ECG were pathological (0.5%): 2 long QT interval, 2 Wolf-Parkinson-White, 1 pathological Q-wave. A second ECG confirmed except for 2 long QT. No structural heart disease was found.

CONCLUSIONS

ECG-screening in newborns is an innocuous, low-cost and parent-well-accepted test that allows us to diagnose asymptomatic but potentially lethal and preventable heart disease; main intervals and waves in our population are describes in this study.

Для цитирования: Cruz Cañete M, Rus Mansilla C, Gómez Lara A, Gavilán Expósito M L, Calleja Cabezas P, Gavilán Pérez M. [Usefulness of electrocardiographic screening in a neonatal population].. Anales de pediatria (Barcelona, Spain : 2003). 2011. DOI: 10.1016/j.anpedi.2010.12.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.