Chetla Nitin, Naidu Trisha, Patel Shivam, Bouras Andrew, Kacham Harshita, Bonagiri Vinisha, Zaman Nasif
Аннотация
INTRODUCTION: Breast MRI, particularly dynamic contrast-enhanced (DCE) MRI, offers high sensitivity in detecting breast lesions but suffers from variability in interpretation. Artificial intelligence (AI) tools like Gemini 2.0 (Google AI, Mountain View, CA) may help streamline and improve diagnostic accuracy. This study evaluates Gemini 2.0's performance in classifying breast lesion status using application programming interface (API)-based image analysis.
METHODS: MRI images were sourced from the publicly available fastMRI Breast dataset, which includes axial DCE-MRI sequences acquired using a 3D Golden-angle Radial Sparse Parallel (GRASP) protocol. Images were converted from DICOM to PNG for compatibility with Gemini 2.0's API. Two binary classification prompts were tested. Prompt 1 distinguished between (A) benign or malignant lesion and (B) negative lesion status using 100 patient scans. Prompt 2 classified (A) benign vs. (B) malignant lesions in a separate set of 180 patient scans. Responses from the Gemini 2.0 API were recorded, and performance was assessed using accuracy, precision, recall, and F1-score.
RESULTS: For prompt 1, Gemini 2.0 achieved 50% accuracy. It identified all benign or malignant lesions (100% recall) but misclassified all negative cases, yielding 0% recall for negative lesion status. The F1-score was 0.67 for benign/malignant lesions and 0 for negative lesions. For prompt 2, the model achieved 52% accuracy. It exhibited 97% recall for malignant lesions but only 7% for benign lesions, reflecting a strong bias toward malignancy. The weighted average F1-score was 0.39.
DISCUSSION: Gemini 2.0 shows promise in flagging lesion presence but lacks the discriminatory power needed to distinguish benign from malignant or negative cases reliably. The high false-positive rate and class imbalance indicate a need for algorithmic refinement and further validation. Larger and more diverse training datasets are necessary to improve performance and reduce bias. Future research should compare AI classifications to radiologist interpretations in a prospective setting to assess clinical utility.
CONCLUSION: Gemini 2.0 offers preliminary utility in breast lesion detection on DCE-MRI, particularly in identifying malignancy. However, its limited specificity and poor differentiation between lesion types underscore the need for continued development before clinical deployment.
METHODS: MRI images were sourced from the publicly available fastMRI Breast dataset, which includes axial DCE-MRI sequences acquired using a 3D Golden-angle Radial Sparse Parallel (GRASP) protocol. Images were converted from DICOM to PNG for compatibility with Gemini 2.0's API. Two binary classification prompts were tested. Prompt 1 distinguished between (A) benign or malignant lesion and (B) negative lesion status using 100 patient scans. Prompt 2 classified (A) benign vs. (B) malignant lesions in a separate set of 180 patient scans. Responses from the Gemini 2.0 API were recorded, and performance was assessed using accuracy, precision, recall, and F1-score.
RESULTS: For prompt 1, Gemini 2.0 achieved 50% accuracy. It identified all benign or malignant lesions (100% recall) but misclassified all negative cases, yielding 0% recall for negative lesion status. The F1-score was 0.67 for benign/malignant lesions and 0 for negative lesions. For prompt 2, the model achieved 52% accuracy. It exhibited 97% recall for malignant lesions but only 7% for benign lesions, reflecting a strong bias toward malignancy. The weighted average F1-score was 0.39.
DISCUSSION: Gemini 2.0 shows promise in flagging lesion presence but lacks the discriminatory power needed to distinguish benign from malignant or negative cases reliably. The high false-positive rate and class imbalance indicate a need for algorithmic refinement and further validation. Larger and more diverse training datasets are necessary to improve performance and reduce bias. Future research should compare AI classifications to radiologist interpretations in a prospective setting to assess clinical utility.
CONCLUSION: Gemini 2.0 offers preliminary utility in breast lesion detection on DCE-MRI, particularly in identifying malignancy. However, its limited specificity and poor differentiation between lesion types underscore the need for continued development before clinical deployment.