m+Medelevator.RU
← Поиск публикаций
Tomography (Ann Arbor, Mich.) · 2026

Imaging of Artificial Tumor Models in an Anatomical Breast Phantom with a Single-Sided Magnetic Particle Imaging Scanner.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

McDonough Christopher, Chrisekos John, Jurj Matthew, Wiacek Alycen, Tonyushkin Alexey

Аннотация

Background: Magnetic Particle Imaging (MPI) is an emerging biomedical imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIONs), providing high contrast, sensitivity, and quantification capabilities without ionizing radiation, making it particularly suitable for cancer diagnostics. Considerable engineering efforts are underway to translate MPI technology to clinical settings. Most of these MPI scanners feature a cylindrical bore geometry similar to that of other clinical imaging modalities, which limits their potential application primarily to head scanning. Methods: We have developed a single-sided MPI scanner designed to expand the modality's applicability to other regions of the human body through a unique hardware design developed in our previous work. Imaging experiments were performed on an anatomical breast phantom containing implanted SPION point sources placed at anatomically plausible locations for breast tumors. These point sources served as artificial tumors for evaluating the system's suitability for breast imaging applications. Results: The scanner successfully detected and clearly resolved the implanted SPION tumors in two orthogonal imaging planes. Tumor positioning was independently validated by ultrasound imaging, confirming MPI's accurate localization. In addition, sensitivity measurements demonstrated a detection limit of 4.0 μg of iron, below the estimated 4.8 μg sensitivity threshold required for breast tumor detection with electronic depth scanning up to 3.5 cm deep. Conclusions: Together, these results demonstrate the capability of a single-sided MPI geometry for breast imaging applications. Imaging an anatomical breast-shaped volume presents significant challenges for MPI due to the size and accessibility constraints of conventional hardware. The results presented highlight the advantages of this approach and support its potential to extend MPI from small-animal imaging to clinically relevant applications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты