AIM: The purpose of this study was to describe the characteristics of women with twin pregnancies who undergo noninvasive prenatal testing (NIPT) as well as the post-partum and neonatal outcomes of such cases in Japan.

METHODS

The study population consisted of women who were pregnant with twins and who underwent NIPT using massively parallel sequencing (MPS) at Nagoya City University Hospital between April 2013 and June 2016. Questionnaires were completed pre-NIPT and post-partum.

RESULTS

Among 4009 women who underwent NIPT during the study period, 75 women (1.9%) were pregnant with twins. Fifteen women (20%) experienced vanishing twin/intrauterine fetal deaths at <22 weeks, and 60 women (80%) had normal twin pregnancies at the time of genetic counseling for NIPT. The use of NIPT was correlated with increased proportions of women using assisted reproductive technology (ART). The test had a high performance, with a false-positive rate of 1.7% and no false negatives.

CONCLUSION

In this study, NIPT had a high performance, with a false positive rate of 1.7% and no false negatives. When treating women with twin pregnancies, the efficacy of NIPT should be explained during genetic counseling. Further larger studies are required to assess the reliability and validity of NIPT in twin pregnancies.

Для цитирования: Takeda Eri, Suzumori Nobuhiro, Kumagai Kyoko, Inuzuka Saki, Oseto Kumiko, Ohigashi Yuka, Yotsumoto Junko, Miyake Hidehiko, Sugiura-Ogasawara Mayumi. Performance and outcomes of noninvasive prenatal testing for twin pregnancies in Japan.. The journal of obstetrics and gynaecology research. 2018. DOI: 10.1111/jog.13744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.