MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0b013e3181d2d04c

Медицинская библиотека · Journal of orthopaedic trauma · 2011

A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate.

Yang Huiguang, Li Zhongze, Zhou Feng, Wang Daoyuan, Zhong Baoliang

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this prospective study was to evaluate the safety, efficacy, and functional outcome of the locked proximal humerus plate (LPHP) to treat proximal humerus fractures.

DESIGN

Prospective clinical trial.

SETTING

University orthopedic center.

PATIENTS: Over a 25-month period, 64 consecutive patients were treated with a LPHP for an unstable or displaced proximal humerus fracture.

INTERVENTION: Demographic data, trauma mechanisms, surgical approaches, and postoperative complications were collected from medical records. Fracture classification according to the Neer classification, radiographic head-shaft angle, and screw tip-articular surface distance in true anteroposterior and axillary lateral radiographs of the shoulder were measured postoperatively.

MAIN OUTCOME MEASUREMENTS: The functional outcome was evaluated with a Constant-Murley (CM) evaluation. The CM score is a validated shoulder-specific scoring system in which patients report subjective findings. The physician reported the objective measurements of the shoulder.

RESULTS

Follow-ups were completed for all of the patients. The overall complication rate was 35.9%, with screw penetration into the glenohumeral joint as the most frequent problem (7.6%). Deep wound infections were observed in 3.1% (n = 2) of the cases and avascular necrosis in 3.1% (n = 2). All complications occurred in 4-part fractures. Subacromial impingement, frozen shoulder, rotator cuff rupture, and wound dehiscence were observed in 3.1% (n = 2), 3.1% (n = 2), 1.6% (n = 1), and 1.6% (n = 1) of the cases, respectively. Multivariate linear regression analysis revealed that the fracture pattern and the presence or absence of medial support were significant predictors of functional outcome (P = 0.026 and P = 0.003, respectively). Patient age (P = 0.581), sex (P = 0.325), and initial tuberosity displacement (varus/extension or valgus/impaction; P = 0.059) were not significantly associated with the CM score.

CONCLUSIONS

The LPHP seems to be a promising implant for the fixation of proximal humerus fractures. However, there are certain limitations that should be mentioned. The number of cases in our study was small, and no safe conclusions can be extracted regarding the rate of avascular necrosis. Additional studies with larger cohorts and longer follow-ups are necessary to better define the appropriate indications for and expected outcomes of this technology.

Для цитирования: Yang Huiguang, Li Zhongze, Zhou Feng, Wang Daoyuan, Zhong Baoliang. A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate.. Journal of orthopaedic trauma. 2011. DOI: 10.1097/bot.0b013e3181d2d04c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.