m+Medelevator.RU
← Поиск публикаций
Multiple sclerosis (Houndmills, Basingstoke, England) · 2026

Influence of OSCAR-IB criteria on test-retest reliability of Spectralis SD-OCT retinal thickness measurements in people with Multiple Sclerosis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bacchetti Anna, McCormack Brenna, Lin Ting-Yi, Filippatou Angeliki G, Gakis Georgios, Pellegrini Nicole, Kinder Evan, Gulati Ananya, Lievers Ernest, Otero-Duran Gabriel, Newsome Scott D, Murphy Olwen, Nourbakhsh Bardia, Fitzgerald Kathryn C, Sotirchos Elias S, Calabresi Peter A, Saidha Shiv

Аннотация

BACKGROUND: Optical coherence tomography (OCT) enables evaluation of inter-eye differences (IEDs) in peri-papillary retinal nerve fiber layer (pRNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thicknesses to identify unilateral optic nerve involvement (UONI), included in the 2024 revised McDonald diagnostic criteria for multiple sclerosis (MS).

OBJECTIVES: To evaluate pRNFL and GCIPL thickness test-retest reliability in scans fulfilling (SFO) versus not fulfilling (SNFO) OSCAR-IB criteria in people with MS using Spectralis SD-OCT.

METHODS: From 164 participants, two scans per eye per protocol (optic nerve head: pRNFL; macular volume: GCIPL) were obtained with Spectralis SD-OCT and classified as SFO or SNFO. Intra-visit intraclass correlation coefficients (ICCs) and coefficients of variation (COVs) quantified reproducibility.

RESULTS: pRNFL thicknesses from SNFO exhibited lower reliability (n = 72, ICC = 0.827, COV = 3.38%), than from SFO (n = 216, ICC = 0.991, COV = 1.14%). GCIPL thicknesses demonstrated excellent reliability from both SFO (n = 199, ICC = 0.997, COV = 0.53%) and SNFO (n = 97, ICC = 0.990, COV = 0.83%). Algorithm failure and low signal strength most affected pRNFL (COV = 7.72%) and GCIPL (COV = 3.34%) reproducibility, respectively.

CONCLUSIONS: OSCAR-IB violations negligibly affected GCIPL reliability, although reduced pRNFL reliability, supporting quality control to avoid erroneous UONI, and suggesting that GCIPL measures may be more robust than pRNFL measures with Spectralis SD-OCT, in contrast to prior Cirrus HD-OCT studies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты