MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urolonc.2026.03.002

Медицинская библиотека · Urologic oncology · 2026

Automation of four nephrometry scores using 3D models in renal cell carcinoma.

Vermijs Saar, Vangeneugden Joris, Demeyere Lara, Termote Marthe, De Visschere Pieter, De Backer Pieter, Berquin Camille, Decaestecker Karel, Debbaut Charlotte, Van Praet Charles

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Nephrometry scores quantify renal tumor complexity to standardize reporting, however, manual calculation is time-consuming and prone to interobserver variability. Furthermore, 2-dimensional preoperative imaging limits anatomical interpretation. Therefore, we developed a fully automated method using 3-dimensional (3D) models to calculate 4 established scoring systems: RENAL, PADUA, C-index and CSA, and benchmarked them against manual calculations for validation.

METHODS

Preoperative CT scans and manually segmented 3D models of 80 patients undergoing robot-assisted partial nephrectomy at Ghent University Hospital were analyzed. 3 observers (student, resident, expert) manually scored each CT.Automated 3D scores were generated using our Python-based algorithm. Discrepant resident-expert scores were re-evaluated to reach consensus for comparison with automatic scores. Interobserver variability was assessed using intraclass correlation coefficients (ICC). Scoring durations were compared using paired t-tests. Pearson correlation coefficients were calculated between automated/manual scores and surgical complexity metrics: estimated blood loss (EBL), operative time (OT), and warm ischemic time (WIT).

RESULTS

Manual interobserver agreement was moderate to good (ICC(2,1) = 0.72-0.90). Re-evaluation was needed in 67 cases (83.75%). Automated scores demonstrated moderate to good agreement with manual consensus (ICC(3,1) = 0.68-0.89) and substantially reduced scoring time (manual = 5.9 minutes vs. automated = 0.2 minutes; p < 0.001). Expert re-evaluation confirmed automated accuracy in 92.9% of reviewed cases. Correlations with EBL, OT, and WIT did not differ significantly between manual and automated methods (p > 0.1).

CONCLUSIONS

Our fully automated 3D model-based calculations of RENAL, PADUA, C-index, and CSA offer improved reproducibility, accuracy and efficiency while maintaining clinical validity.

Для цитирования: Vermijs Saar, Vangeneugden Joris, Demeyere Lara, Termote Marthe, De Visschere Pieter, De Backer Pieter, Berquin Camille, Decaestecker Karel, Debbaut Charlotte, Van Praet Charles. Automation of four nephrometry scores using 3D models in renal cell carcinoma.. Urologic oncology. 2026. DOI: 10.1016/j.urolonc.2026.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.