BACKGROUND

The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom energy-storing carbon fiber ankle-foot orthosis developed for lower-extremity trauma patients. Studies conducted at the military treatment facility where the IDEO was developed demonstrated benefits of the IDEO when used with the Return to Run Physical Therapy (RTR PT) program. The current study was designed to determine if results could be replicated at other military treatment facilities and to examine whether early performance gains in patient-reported functional outcomes remained at 12 months.

METHODS

Study participants included service members who had functional deficits that interfered with daily activities at least 1 year after a traumatic unilateral lower-extremity injury at or below the knee. Participants were evaluated before receiving the IDEO, immediately following completion of RTR PT, and at 6 and 12 months. Agility, strength/power, and speed were assessed using well-established performance tests. Self-reported function was measured using the Short Musculoskeletal Function Assessment (SMFA). The Orthotics and Prosthetics Users' Survey was administered to assess satisfaction with the IDEO. Of 87 participants with complete baseline data, 6 did not complete any physical therapy and were excluded from the analysis. Follow-up rates immediately following completion of the RTR PT and at 6 and 12 months were 88%, 75%, and 79%, respectively.

RESULTS

Compared with baseline, improvement at completion of RTR PT was observed in all but 1 performance test. SMFA scores for all domains except hand and arm function were lower (improved function) at 6 and 12 months. Satisfaction with the IDEO was high following completion of RTR PT, with some attenuation at the time of follow-up.

CONCLUSIONS

This study adds to the evidence supporting the efficacy of the IDEO coupled with RTR PT. However, despite improvement in both performance and self-reported functioning, deficits persist compared with population norms.

LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Potter Benjamin K, Sheu Robert G, Stinner Daniel, Fergason John, Hsu Joseph R, Kuhn Kevin, Owens Johnny G, Rivera Jessica, Shawen Scott B, Wilken Jason M, DeSanto Jennifer, Huang Yanjie, Scharfstein Daniel O, MacKenzie Ellen J. Multisite Evaluation of a Custom Energy-Storing Carbon Fiber Orthosis for Patients with Residual Disability After Lower-Limb Trauma.. The Journal of bone and joint surgery. American volume. 2018. DOI: 10.2106/jbjs.18.00213.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.