MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s1677-5538.ibju.2017.0243

Медицинская библиотека · International braz j urol : official journal of the Brazilian Society of Urology · 2018

Evaluation of urodynamic parameters after sling surgery in men with post-prostatectomy urinary incontinence.

Paiva Odair Gomes, Lima João Paulo Cunha, Bezerra Carlos Alberto

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate urodynamic alterations after sub-urethral sling surgery (SSU) in patients with post-prostatectomy urinary incontinence (PPUI).

MATERIALS AND

METHODS

We evaluated data of 22 patients submitted to radical prostatectomy (RP) or transurethral resection of prostate (TURP) that presented post-surgical urinary incontinence and were treated with SSU implant in a pilot study previously performed in our institution.

METHODS

Those patients with PPUI were evaluated by urodynamic exam (UD) before and after surgery, and the parameters were compared, including uroflow, cystometry and micturition study. Exclusion criteria included patients without pre-operatory urodynamic study, those with urethral stenosis, those not healed of prostate cancer, patients without clinical conditions to be submitted to urodynamic study and those with severe neurological diseases or that refused to sign the consent form. Results were analyzed statistically by Fisher, Wilcoxon or Mann-Whitney tests.

RESULTS

During free uroflow, none parameters showed any statistical significant differences. During cystometry, there were also no statistical differences and the same was observed at pressure versus flow study; the exception was at maximal flow detrusor pressure (PdetQmax), that was lower at post-operatory (p=0.028). In relation to the presence of urinary dysfunctions associated to PPUI, we observed a significant reduction of detrusor overactivity (p=0.035) in relation to pre-operatory period.

CONCLUSION

SSU surgery significantly reduced detrusor overactivity and PdetQMax; however, there were no alterations of other evaluated urodynamic parameters.

Для цитирования: Paiva Odair Gomes, Lima João Paulo Cunha, Bezerra Carlos Alberto. Evaluation of urodynamic parameters after sling surgery in men with post-prostatectomy urinary incontinence.. International braz j urol : official journal of the Brazilian Society of Urology. 2018. DOI: 10.1590/s1677-5538.ibju.2017.0243.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.