Micellar HPLC Method for Simultaneous Determination of Ethamsylate and Mefenamic Acid in Presence of Their Main Impurities and Degradation Products.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ibrahim Fawzia, Sharaf El-Din Mohie K, El-Deen Asmaa Kamal, Shimizu Kuniyoshi

Аннотация

An eco-friendly sensitive, rapid and less hazardous micellar liquid chromatographic method was developed and validated for the simultaneous analysis of ethamsylate (ETM) and mefenamic acid (MFA) in the presence of hydroquinone (HQ) and 2,3-dimethylaniline (DMA) the main impurities of ETM and MFA, respectively. Good chromatographic separation was attained using Eclipse XDB-C8 column (150 mm × 4.6 mm, 5 μm particle size) adopting UV detection at 300 nm with micellar mobile phase consisting of 0.12 M sodium dodecyl sulfate, 0.3% triethylamine and 15% 2-propanol in 0.02 M orthophosphoric acid (pH 7.0) at 1.0 mL/min. The analytes were well resolved in <6.0 min, ETM (tR = 1.55 min), HQ (tR = 1.95 min), MFA (tR = 4.55 min) and DMA (tR = 5.80 min). Different validation parameters were examined as recommended by international conference on harmonization (ICH) guidelines. The method was linear over the concentration ranges of 0.5-18.0, 0.5-20.0, 0.01-0.5 and 0.02-0.2 µg/mL with limits of detection of 0.118, 0.159, 0.005 and 0.005 µg/mL and limits of quantification of 0.358, 0.482, 0.014 and 0.015 µg/mL for ETM, MFA, HQ and DMA, respectively. The suggested method was successfully applied for the determination of the two drugs in their bulk powder, laboratory-prepared mixtures, single-ingredient and co-formulated tablets. The obtained results were in accordance with those of the comparison method. The method can also detect trace amounts of HQ and DMA as the main impurities of ETM and MFA, respectively, within the BP limit (0.1%) for both impurities. Furthermore, it is a stability-indicating one for the determination of ETM in its pure form, single-component tablet and co-formulated tablets with other drugs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты