Photographic Reading Center of the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT): Methods and Baseline Results.
Аннотация
PURPOSE: To describe the methods used by the Photographic Reading Center (PRC) of the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT) and to report baseline assessments of papilledema severity in participants.
METHODS
Stereoscopic digital images centered on the optic disc and the macula were collected using certified personnel and photographic equipment. Certification of the camera system included standardization and calibration using a model eye. Lay readers assessed disc photos of all eyes using the Frisén grade and performed quantitative measurements of papilledema. Frisén grades by PRC were compared with site investigator clinical grades. Spearman rank correlations were used to quantify associations among disc features and selected clinical variables.
RESULTS
Frisén grades according to the PRC and site investigator's grades, matched exactly in 48% of the study eyes and 42% of the fellow eyes and within one grade in 94% of the study eyes and 92% of the fellow eyes. Frisén grade was strongly correlated (r > 0.65, P < 0.0001) with quantitative measures of disc area. Cerebrospinal fluid pressure was weakly associated with Frisén grade and disc area determinations (r ≤ 0.31). Neither Frisén grade nor any fundus feature was associated with perimetric mean deviation.
CONCLUSIONS
In a prospective clinical trial, lay readers agreed reasonably well with physicians in assessing Frisén grade. Standardization of camera systems enhanced consistency of photographic quality across study sites. Images were affected more by sensors with poor dynamic range than by poor resolution. Frisén grade is highly correlated with quantitative assessment of disc area. (ClinicalTrials.gov number, NCT01003639.).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.