m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2026

Integration of PRAETORIAN Score, defibrillation testing and follow-up outcomes for the assessment of conversion failure in patients with subcutaneous implantable cardioverter defibrillator: Results from the iSUSI registry.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schiavone Marco, Gasperetti Alessio, Tilz Roland, Kuschyk Jürgen, Breitenstein Alexander, Laredo Mikael, Mitacchione Gianfranco, Compagnucci Paolo, Ricciardi Danilo, Bertini Matteo, Gulletta Simone, Martinek Martin, Kaiser Lukas, Zerjav Dylan C, Nafisio Vincenzo, Santini Luca, Casella Michela, Rovaris Giovanni, Vogler Julia, Di Biase Luigi, Tondo Claudio, Biffi Mauro, Forleo Giovanni B, iSUSI investigators

Аннотация

BACKGROUND: Although reports of good clinical outcomes after avoiding defibrillation testing (DFT) during subcutaneous implantable cardioverter defibrillator (S-ICD) implantation have increased over recent years, current guidelines still recommend performing DFT at the time of implant.

OBJECTIVE: We aimed to identify predictors of conversion failure in a real-world S-ICD population and assess whether PRAETORIAN score performance is improved by additional clinical variables.

METHODS: We analyzed 1063 patients from the international subcutaneous implantable cardioverter defibrillator (iSUSI) registry with available imaging and complete follow-up. The primary endpoint was a composite of DFT failure and ineffective appropriate shocks during follow-up. PRAETORIAN score and individual components were assessed, and receiver operating characteristic curve analysis with DeLong's test was used to evaluate model performance.

RESULTS: Patients were classified into low (76.6%), intermediate (16.3%), and high-risk (7.2%) PRAETORIAN score categories. Among 748 patients who underwent DFT, 64 (8.6%) experienced DFT failure; 17 ineffective shocks occurred during follow-up. Primary outcome occurred in 4.5% of low, 6.7% of intermediate-, and 16.8% of high-risk patients. PRAETORIAN score step 1, anterior generator position at PRAETORIAN score step 2 (odds ratio 2.3 [1.2-4.2], P = .006), high body mass index (BMI) and post-shock impedance, independently predicted conversion failure. Overall PRAETORIAN score (area under the curve [AUC] 0.71) outperformed individual steps (step 1-3 AUCs: 0.68-0.70; P > .05 for all comparisons). A multivariable model combining PRAETORIAN score, BMI, and impedance significantly improved predictive accuracy (AUC 0.78 vs 0.71; P = .0078).

CONCLUSION: PRAETORIAN score, BMI, and impedance are independent predictors of defibrillation failure. Their combined use may improve risk stratification and may help guide clinical decision-making, especially when DFT is omitted.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты