MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-002-1710-3

Медицинская библиотека · Analytical and bioanalytical chemistry · 2003

High-performance liquid chromatographic determination of cocaine and benzoylecgonine by direct injection of human blood plasma sample into an alkyl-diol-silica (ADS) precolumn.

Brunetto Rosario, Gutiérrez Lubin, Delgado Yelitza, Gallignani Máximo, Burguera José Luis, Burguera Marcela

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A column-switching high-performance liquid chromatographic method with UV detection for the determination of cocaine (COC) and benzoylecgonine (BZE) in human blood plasma samples is described. The method uses an alkyl-diol-silica ADS-C18 extraction precolumn. A 50- micro L plasma sample was introduced to the ADS precolumn in order to separate the analytes from proteins and endogenous compounds. The fraction containing COC and BZE was back-flushed and transferred to an Alltech mixed-mode C(18)/cation-exchange analytical column for final separation. The validation of the method revealed quantitative recoveries from 95.0 to 99.0% for COC at three different concentrations (0.5, 1.0 and 2.0 micro g mL(-1)), and from 96.0 to 99.0% for BZE at the same concentration levels with coefficients of variation <4.00% (n=5). The detection limit (signal to noise ratio (S/N)>3) was 0.03 micro g mL(-1) for all the compounds with an injection volume of 50 micro L. However, it was possible to enhance the sensitivity further by injecting larger plasma volumes, up to 200 micro L, at the same optimal conditions. The overlap of sample preparation, analysis and reconditioning of the extraction column, increase the overall sample throughput to 5 samples h(-1). The developed method has been applied to human blood plasma samples from subjects suspected of cocaine abuse.

Для цитирования: Brunetto Rosario, Gutiérrez Lubin, Delgado Yelitza, Gallignani Máximo, Burguera José Luis, Burguera Marcela. High-performance liquid chromatographic determination of cocaine and benzoylecgonine by direct injection of human blood plasma sample into an alkyl-diol-silica (ADS) precolumn.. Analytical and bioanalytical chemistry. 2003. DOI: 10.1007/s00216-002-1710-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.