DOI 10.1007/s00415-024-12624-6
Phosphorylated tau 181 (p-tau181) as an innovative, fast and robust biomarker for cerebrospinal fluid leaks.
Аннотация
BACKGROUND
Cerebrospinal fluid (CSF) leaks can lead to serious complications if left untreated, making rapid and accurate diagnosis essential. Biomarkers such as β2-transferrin (B2TRF) and β-trace protein are used to detect CSF leaks, but their limitations warrant the exploration of alternative markers. This study investigates the potential of phosphorylated tau at threonine 181 (p-tau181) as a biomarker for CSF leaks.
METHODS
Samples from 56 subjects were analyzed for B2TRF and p-tau181 using immunoaffinity blotting and chemiluminescent enzyme immunoassay, respectively. Data analysis included Mann-Whitney test to assess the overall difference in median p-tau181 concentrations between B2TRF positive and negative patients and a receiver operating characteristic (ROC) curve analysis to determine optimal p-tau181 cutoff values for predicting B2TRF positivity.
RESULTS
p-tau181 levels were significantly higher in B2TRF positive samples compared to negative samples (p < 0.001). ROC analysis showed high diagnostic performance for p-tau181, with an optimal cutoff of 13.22 pg/mL providing 92.0% sensitivity and 93.1% specificity. Excluding hemolyzed samples improved further the diagnostic performances, maintaining high sensitivity (90.9%) and achieving perfect specificity (100.0%).
CONCLUSIONS
This study highlights the potential of p-tau181 as a valuable biomarker for the detection of CSF leaks due to its high diagnostic accuracy and practical advantages over the current biomarkers. The characteristics of p-tau181 assay being both quantitative and rapid, with high diagnostic accuracy, suggest that it could be a valuable tool for the detection of CSF leaks. Further research are now needed to validate these findings.