MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00421-023-05174-8

Медицинская библиотека · European journal of applied physiology · 2023

The effects of standardised versus individualised seat height on 1-minute sit-to-stand test performance in healthy individuals: a randomised crossover trial.

Kuhn Manuel, Vollenweider Sibylle, Clarenbach Christian F, Kohlbrenner Dario

Рандомизированное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: We aimed to (i) investigate differences in 1-minute sit-to-stand test (1MSTST) performance (i.e., the number of repetitions) between a standardised modality (i.e., starting from a conventional chair with 46 cm seat height) and an individualised modality (i.e., starting with a knee joint flexion angle of 90°), and to (ii) quantify the influence of tibia and femur length on 1MSTST performance.

METHODS

Healthy participants were recruited for this randomised crossover study, performing each 1MSTST modality twice in a randomised order. The primary outcome was the number of repetitions in the 1MSTST. Secondary endpoints were the acute responses in peripheral oxygen saturation, heart rate, and leg fatigue and dyspnoea. Additionally, we investigated correlations of performance with knee extensor strength in both modalities.

RESULTS

Thirty participants were recruited and completed the study. They achieved significantly less repetitions in the standardised 1MSTST compared to the individualised 1MSTST (B = - 12.1, 95% confidence interval [95% CI] =  - 14.8/- 9.4, p < 0.001). We found a significant effect of femur length on 1MSTST performance (B = - 1.6, 95% CI = - 2.6/- 0.7, p = 0.01), tibia length showed significant interaction with the 1MSTST modality (B = 1.2, 95% CI = 0.2/2.2, p = 0.03).

CONCLUSION

An individualisation of the 1MSTST starting position to 90° knee flexion angle leads to more repetitions compared to the traditional starting position. The higher repetition count is explained by controlling for differences in tibia length. We recommend individualisation of the 1MSTST, enabling more valid comparisons across populations and study samples.

TRIAL REGISTRATION NUMBER: http://www.

CLINICALTRIALS: gov , NCT04772417.

TRIAL REGISTRATION DATE: February 26, 2021.

Для цитирования: Kuhn Manuel, Vollenweider Sibylle, Clarenbach Christian F, Kohlbrenner Dario. The effects of standardised versus individualised seat height on 1-minute sit-to-stand test performance in healthy individuals: a randomised crossover trial.. European journal of applied physiology. 2023. DOI: 10.1007/s00421-023-05174-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.