Cardiology in the young · 2020
Pulmonary atresia with ventricular septal defect and tetralogy of Fallot: transannular path augmentation versus systemic to pulmonary artery shunt for first-stage palliation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lenoir Marien, Fouilloux Virginie, Desnous Beatrice, Rahmani Bilal, El Gueddari Nabila, Ovaert Caroline, Aries Edouard, El Louali Fedoua, Aldebert Philippe, Metras Dominique, Macé Loic
Аннотация
BACKGROUND: Pulmonary atresia with ventricular septal defect and severe tetralogy of Fallot require a palliative procedure for pulmonary artery rehabilitation. For first-stage palliation, two main surgical options are still debated: right ventricle to pulmonary artery connection and modified Blalock-Taussig shunt. We compared the clinical outcomes of the two procedures.
METHODS: From 1995 to 2018, 88 patients needed palliation (pulmonary atresia with ventricular septal defect n = 47; tetralogy of Fallot n = 41). Among these patients, 70 modified Blalock-Taussig shunt and 18 transannular path augmentation were performed before 6 months of age. Using a 1:1 propensity score match analysis, 20 patients were included in the analysis. The primary outcome was in-hospital mortality and pulmonary artery growth.
RESULTS: After matching, the pre-operative Nakata was smaller in transannular path augmentation 54 ± 24 mm2/m2 than modified Blalock-Taussig shunt 109 ± 31 mm2/m2 (p < 0.001). The age and weight were similar (p = 0.31 and p = 0.9, respectively). There was no difference in in-hospital mortality (p = 0.3). The Nakata index before biventricular repair and delta Nakata were smaller in modified Blalock-Taussig shunt group (206 ± 80 mm2/m2, 75 ± 103 mm2/m2) than transannular path augmentation (365 ± 170 mm2/m2, 214 ± 165 mm2/m2; p = 0.03; p < 0.001). Median time to biventricular repair was similar (p = 0.46). The rate of interstage reintervention was similar (p = 0.63).
CONCLUSIONS: The transannular path augmentation is better for the rehabilitation of the native pulmonary artery. Despite a smaller pulmonary artery, right ventricle to pulmonary artery connection is equivalent to modified Blalock-Taussig shunt for rate of biventricular repair and time to biventricular repair.
METHODS: From 1995 to 2018, 88 patients needed palliation (pulmonary atresia with ventricular septal defect n = 47; tetralogy of Fallot n = 41). Among these patients, 70 modified Blalock-Taussig shunt and 18 transannular path augmentation were performed before 6 months of age. Using a 1:1 propensity score match analysis, 20 patients were included in the analysis. The primary outcome was in-hospital mortality and pulmonary artery growth.
RESULTS: After matching, the pre-operative Nakata was smaller in transannular path augmentation 54 ± 24 mm2/m2 than modified Blalock-Taussig shunt 109 ± 31 mm2/m2 (p < 0.001). The age and weight were similar (p = 0.31 and p = 0.9, respectively). There was no difference in in-hospital mortality (p = 0.3). The Nakata index before biventricular repair and delta Nakata were smaller in modified Blalock-Taussig shunt group (206 ± 80 mm2/m2, 75 ± 103 mm2/m2) than transannular path augmentation (365 ± 170 mm2/m2, 214 ± 165 mm2/m2; p = 0.03; p < 0.001). Median time to biventricular repair was similar (p = 0.46). The rate of interstage reintervention was similar (p = 0.63).
CONCLUSIONS: The transannular path augmentation is better for the rehabilitation of the native pulmonary artery. Despite a smaller pulmonary artery, right ventricle to pulmonary artery connection is equivalent to modified Blalock-Taussig shunt for rate of biventricular repair and time to biventricular repair.