MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2008.03.038

Медицинская библиотека · Analytica chimica acta · 2008

Dispersive liquid-liquid microextraction followed by reversed phase-high performance liquid chromatography for the determination of polybrominated diphenyl ethers at trace levels in landfill leachate and environmental water samples.

Li Yanyan, Wei Guohui, Hu Jia, Liu Xiujuan, Zhao Xinna, Wang Xuedong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 microL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL(-1) for BDE-28 and BDE-99, and 0.1-100 ng mL(-1) for BDE-47 and BDE-209, respectively. Coefficients of correlation (r(2)) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL(-1) for BDE-28 and BDE-99, and 100 ng mL(-1) for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n=5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL(-1) (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL(-1) were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.

Для цитирования: Li Yanyan, Wei Guohui, Hu Jia, Liu Xiujuan, Zhao Xinna, Wang Xuedong. Dispersive liquid-liquid microextraction followed by reversed phase-high performance liquid chromatography for the determination of polybrominated diphenyl ethers at trace levels in landfill leachate and environmental water samples.. Analytica chimica acta. 2008. DOI: 10.1016/j.aca.2008.03.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.