MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000002440

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025

Comparison of Hemodynamic Circulation in Pulsatile and Nonpulsatile Extracorporeal Membrane Oxygenation Systems Using an In-Vitro Heart Model.

Yoo Changyoung, Jang Hyun-Woo, Kang Seongmin, Choi Seong-Wook

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study conducts an in-vitro experiment using a mock circulation system that mimics human circulation to assess the veno-arterial extracorporeal membrane oxygenation (ECMO) system. This study aims to compare the hemodynamic effects of centrifugal and pulsatile ECMO systems on the body using an in-vitro cardiogenic shock model. The heart model used in this study involves a contracting blood sac with inlet and outlet valves, capable of maintaining arterial pressure between 80 and 120 mm Hg while delivering a blood flow of 1.8-2 L/min, effectively replicating a cardiogenic shock model. The contraction force in the heart model was generated using a pneumatic cylinder and gradually decreased to simulate reduced cardiac function. The initial blood flow rates of both ECMO systems were maintained at 2 L/min under identical conditions for a fair comparison. Upon reducing the stroke volume of the heart to 35 ml, the ECMO system with counter-pulsation control increased the cardiac output by 10.7% and systemic circulation by 3.8% compared with the conventional ECMO system. This study demonstrates the hemodynamic benefits provided by the sustained counter-pulsation in an in-vitro weakened heart model. Pulsatile flow ECMO systems may serve as an alternative to address the limitations of continuous flow ECMO systems.

Другие публикации по теме

Extracorporeal Membrane OxygenationPulsatile FlowHemodynamicsModels, Cardiovascular
Для цитирования: Yoo Changyoung, Jang Hyun-Woo, Kang Seongmin, Choi Seong-Wook. Comparison of Hemodynamic Circulation in Pulsatile and Nonpulsatile Extracorporeal Membrane Oxygenation Systems Using an In-Vitro Heart Model.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2025. DOI: 10.1097/mat.0000000000002440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.