MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.215.2.r00ma13529

Медицинская библиотека · Radiology · 2000

Poststress measurements of left ventricular function with gated perfusion SPECT: comparison with resting measurements by using a same-day perfusion-function protocol.

Borges-Neto S, Javaid A, Shaw L K, Kong D F, Hanson M W, Pagnanelli R A, Ravizzini G, Coleman R E

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the relationship between the development of ischemia during stress testing and the changes in left ventricular ejection fraction (LVEF) measurements obtained after stress and at rest with a same-day perfusion-function imaging protocol.

MATERIALS AND

METHODS

One hundred twenty-six patients underwent a same-day rest-stress (61%) or stress-rest (39%) protocol and gated single photon emission computed tomography (SPECT). Perfusion analysis was performed with a 12-segment model. Defects were scored (0 = no defect, 1 = mild defect, 2 = moderate defect, and 3 = severe defect); differences between the summed stress and resting scores of greater than three indicated substantial ischemia.

RESULTS

Resting and poststress LVEFs correlated significantly (r = 0.97, P <.001); however, patients with and patients without ischemia had significant differences in poststress versus resting LVEFs (-4.0 vs 1.0, respectively; P <.01). In patients with ischemia versus patients without ischemia, subgroup analysis stress-rest (-2.5 vs 1.0, P =.047) and rest-stress (-4.0 vs 1.0, P =.006) protocols yielded similar results.

CONCLUSION

In patients with clinically important stress-induced perfusion abnormalities, the LVEF after stress was significantly lower than the LVEF at rest with same-day rest-stress and stress-rest imaging protocols. In the clinical setting, poststress LVEFs may be lower than true resting measurements, particularly in patients with moderate to severe stress-induced ischemia.

Для цитирования: Borges-Neto S, Javaid A, Shaw L K, Kong D F, Hanson M W, Pagnanelli R A, Ravizzini G, Coleman R E. Poststress measurements of left ventricular function with gated perfusion SPECT: comparison with resting measurements by using a same-day perfusion-function protocol.. Radiology. 2000. DOI: 10.1148/radiology.215.2.r00ma13529.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.