MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10396-021-01110-5

Медицинская библиотека · Journal of medical ultrasonics (2001) · 2021

Elucidation of spleen elasticity and viscosity in a carbon tetrachloride rat model of liver cirrhosis using a new ultrasound elastography.

Furuichi Yoshihiro, Sugimoto Katsutoshi, Oshiro Hisashi, Abe Masakazu, Takeuchi Hirohito, Yoshimasu Yuu, Itoi Takao

СтатьяПеревод в очереди

Аннотация

PURPOSE: Measurement of spleen stiffness (SS) using ultrasound (US) elastography is useful for predicting portal hypertension. However, the mechanism leading to increased SS remains unclear. We jointly developed a new US elastography system (Aplio i-series, Canon Medical Systems) that can easily measure organ viscosity (dispersion slope: DS). We analyzed the cause of increased SS by calculating the shear wave speed (SWs, which reflects fibrosis) and DS of the spleen in carbon tetrachloride (CCL4) rat liver cirrhosis models.

METHODS

A total of 13 Sprague-Dawley rats were randomly divided into four groups (C group: 3 rats as control, 2D group: 3 rats injected with CCL4 twice in 1 week, 4D group: 4 rats injected 4 times in 1 week, 6W group: 3 rats injected twice a week for 6 weeks). The SWs and the DS of each group were calculated, and histopathological analysis was performed.

RESULTS

The spleen SWs of the 6W group was significantly higher than that of the C group (p = 0.044). The spleen DS did not change after CCL4. The liver SWs of the 4D and 6W groups was significantly higher than that of the C group (p = 0.012 and 0.007, respectively) with fibrosis change on histopathology, and the DS of the 4D group was significantly higher than that of the C group (p = 0.033). Splenic fibrosis was confirmed in the 6W group, but inflammation and necrosis were not seen.

CONCLUSION

SS increased due to fibrosis and can be predicted based on SWs and DS values.

Для цитирования: Furuichi Yoshihiro, Sugimoto Katsutoshi, Oshiro Hisashi, Abe Masakazu, Takeuchi Hirohito, Yoshimasu Yuu, Itoi Takao. Elucidation of spleen elasticity and viscosity in a carbon tetrachloride rat model of liver cirrhosis using a new ultrasound elastography.. Journal of medical ultrasonics (2001). 2021. DOI: 10.1007/s10396-021-01110-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.