MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00006250-199406000-00012

Медицинская библиотека · Obstetrics and gynecology · 1994

Comparative efficacy of two sonographic measurements for the detection of aberrations in the amniotic fluid volume and the effect of amniotic fluid volume on pregnancy outcome.

Magann E F, Morton M L, Nolan T E, Martin J N, Whitworth N S, Morrison J C

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine in pregnant women with preterm labor the relative efficacy of the amniotic fluid index (AFI) and the two-diameter pocket to detect abnormalities in amniotic fluid volume (AFV), and to relate these findings to pregnancy outcome.

METHODS

Fifty-seven healthy women with preterm labor underwent amniocentesis in the third trimester to detect subclinical chorioamnionitis and assess fetal lung maturity. The AFV was estimated by the AFI and two-diameter-pocket methods, then confirmed by a dye (aminohippurate sodium)-dilution technique. Each labor was evaluated for severe variable decelerations requiring amnioinfusion, fetal distress resulting in cesarean delivery, and a 5-minute Apgar score below 7.

RESULTS

Using fluid volume confirmed by dye dilution, the AFI correctly diagnosed AFV as low (less than 500 mL) in only two of 23 (8.7%) patients, compared to 14 of 23 (61%) for the two-diameter pocket (P < .001). Fetal distress requiring cesarean delivery occurred significantly more often in the hydramnios group (three of six) compared to those with normal AFV (one of 23) (P < .03), and approached significance in the oligohydramnios group (two of 21) (P = .056). There were no significant differences among the three patient groups regarding the need for amnioinfusion for severe variable decelerations or the occurrence of 5-minute Apgar scores below 7.

CONCLUSIONS

Compared to the AFI, the two-diameter pocket is a superior sonographic measurement for the detection of oligohydramnios. In an otherwise low-risk pregnancy with preterm labor, oligohydramnios is associated with no greater risk for an adverse outcome than is a normal AFV.

Для цитирования: Magann E F, Morton M L, Nolan T E, Martin J N, Whitworth N S, Morrison J C. Comparative efficacy of two sonographic measurements for the detection of aberrations in the amniotic fluid volume and the effect of amniotic fluid volume on pregnancy outcome.. Obstetrics and gynecology. 1994. DOI: 10.1097/00006250-199406000-00012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.