MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2024.03.017

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2024

Transcatheter aortic valve replacement achieves similar predicted effective orifice area to surgical aortic valve replacement in bicuspid aortic stenosis.

Connolly John E, Herrmann Howard C, Atluri Pavan, Desai Nimesh, Fiorilli Paul N, Giri Jay, Li Robert H, Kobayashi Taisei, Nathan Ashwin S, Szeto Wilson Y, Grimm Joshua C

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Studies comparing transcatheter and surgical aortic valve replacement (TAVR and SAVR) for patients with trileaflet aortic stenosis (AS) have found similar or larger effective orifice area (EOA) for TAVR prostheses. To our knowledge, no studies have compared EOA in patients undergoing TAVR versus SAVR for bicuspid AS.

METHODS

We retrospectively compared prosthetic valvular sizing and predicted EOA for patients with bicuspid AS undergoing TAVR or SAVR at our institution between January 1, 2016, and December 31, 2021. We excluded patients undergoing procedures for indications other than AS and those without a pre-procedural gated Chest CT. Comparisons included demographics, comorbidities, annular size, prosthetic valve size, predicted EOA and prosthesis-patient mismatch (PPM) for TAVR (N = 78) and SAVR (N = 74) cohorts.

RESULTS

TAVR patients had smaller pre-procedural annular area (501.7 mm2 vs. 571.8 mm2, p < 0.05) and annular perimeter (80.6 mm vs. 86.5 mm, p < 0.05), but larger mean implanted prosthetic valve size (26.4 mm vs 24.2 mm, p < 0.001) compared to SAVR patients. No differences were observed in predicted EOA, predicted EOA indexed to patient body surface area (EOAi), or predicted PPM grade between TAVR and SAVR groups, including in cohorts sorted by pre-procedural annular size.

CONCLUSIONS

For bicuspid AS patients undergoing aortic valve replacement, TAVR achieves similar predicted EOA to SAVR. These data support the use of TAVR in selected patients with bicuspid AS and can inform heart team discussions.

Для цитирования: Connolly John E, Herrmann Howard C, Atluri Pavan, Desai Nimesh, Fiorilli Paul N, Giri Jay, Li Robert H, Kobayashi Taisei, Nathan Ashwin S, Szeto Wilson Y, Grimm Joshua C. Transcatheter aortic valve replacement achieves similar predicted effective orifice area to surgical aortic valve replacement in bicuspid aortic stenosis.. Cardiovascular revascularization medicine : including molecular interventions. 2024. DOI: 10.1016/j.carrev.2024.03.017.