m+Medelevator.RU
← Поиск публикаций
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Tumor control probability analysis in carbon-ion radiotherapy for prostate cancer considering the oxygen effect.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wakisaka Yushi, Fukuda Shuka, Tsubouchi Toshiro, Hamatani Noriaki, Yagi Masashi, Nakata Mayu, Tominaga Yuki, Hayashi Kazuhiko, Takashina Masaaki, Minami Kazumasa, Nishio Teiji, Kanai Tatsuaki

Аннотация

PURPOSE: Carbon ion radiotherapy (CIRT) is expected to be effective against hypoxic tumors due to its lower oxygen enhancement ratio (OER) compared to X-ray radiotherapy (XRT). OER is expected to have a significant impact on therapeutic efficacy, especially for prostate cancer, which has low oxygen partial pressure. This study aimed to derive OERs for photon and carbon-ion spread-out Bragg peak (SOBP) irradiation through cellular experiments and incorporate them into the tumor control probability (TCP) function to test consistency with clinical outcomes.

METHODS: To derive the OER for photons and the OERs at three depths (proximal, center, and distal) within the carbon-ion SOBP, the dose-dependent survival rate of the prostate cancer cell line PC3 was measured under both aerobic and hypoxic conditions. TCP functions incorporating dose-dependent OERs based on clinical prescription doses were fitted to clinical outcomes of prostate cancer treated with XRT and CIRT to test the clinical relevance of the obtained OERs.

RESULTS: The OERs at 10% survival for PC3 cells were 2.12 ± 0.68 for photons, and 1.70 ± 0.13, 1.65 ± 0.19, and 1.56 ± 0.13 at the proximal, center, and distal depths of the carbon-ion SOBP, respectively. The TCP functions calculated using dose-dependent OERs were not inconsistent with the clinical outcomes for both XRT and CIRT, supporting the clinical relevance of the OERs derived from cell experiments.

CONCLUSION: The carbon-ion SOBP used in prostate cancer treatment has a lower OER than photons, suggesting its potential effectiveness against hypoxic tumors.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты