MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18502/fid.v22i5.17838

Медицинская библиотека · Frontiers in dentistry · 2025

Dimensional Stability and Accuracy of Silicone Impression Materials after Ozone Water Disinfection: An In Vitro Study.

Kutralanathan Abinaya, Chidambaranathan Ahila Singaravel, Balasubramaniam Muthukumar

СтатьяПеревод в очереди

Аннотация

Objectives

This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. Materials and

Methods

According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05).

Results

The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001).

Conclusion

Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.

Для цитирования: Kutralanathan Abinaya, Chidambaranathan Ahila Singaravel, Balasubramaniam Muthukumar. Dimensional Stability and Accuracy of Silicone Impression Materials after Ozone Water Disinfection: An In Vitro Study.. Frontiers in dentistry. 2025. DOI: 10.18502/fid.v22i5.17838.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.