MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21470/1678-9741-2020-0059

Медицинская библиотека · Brazilian journal of cardiovascular surgery · 2021

Short-term outcome of Polytetrafluoroethylene Membrane Valve versus Transannular Pericardial patch Reconstruction of Right Ventricular Outflow Tract in Tetralogy of Fallot: a Randomized Controlled Trial.

Rawat Sanjib, Jaswal Vivek, Thingnam Shyam Kumar Singh, Singh Harkant, Mahajan Sachin, Kynta Reuben Lamiaki, Puri Goverdhan Dutt, Rohit Manoj Kumar

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Reconstruction of right ventricular outflow tract during primary repair of tetralogy of Fallot often requires the placement of a transannular patch which results in pulmonary regurgitation (PR). We compared the short-term outcomes of bicuspid polytetrafluoroethylene membrane valve versus transannular pericardial patch reconstruction of the right ventricular outflow tract.

METHODS

Thirty consecutive patients undergoing primary repair of tetralogy of Fallot were randomly allocated to two groups - polytetrafluoroethylene valve (PTFEV) group (n=15) and transannular pericardial patch (TAP) group (n=15). The two groups had similar preoperative demographic characteristics. We compared the short-term clinical and echocardiographic outcomes between these groups. The transthoracic echocardiographic follow-up was performed at one week, one month and six months after surgery.

RESULTS

The PTFEV group had significantly lower central venous pressure in the immediate postoperative period compared to the TAP group (7.60±2.06 vs. 10.13±1.73, P=0.002). Extubation time was significantly shorter in the PTFEV group compared to the TAP group (12.93±7.55 hrs vs. 22.23±15.11 hrs, P=0.04). PR in the PTFEV group was absent in five patients at 24 hours post-surgery. At the study endpoint, PR was absent in six, trivial in one and mild in eight patients in the PTFEV group compared to TAP group, where all 15 patients had severe PR.

CONCLUSION

The bicuspid polytetrafluoroethylene membrane valves significantly decrease the central venous pressure in the immediate postoperative period, facilitate early extubation and, thus, prevent ventilator-related comorbidities. They achieve a high degree of pulmonary competence and do not increase the right ventricular outflow tract gradient in short-term follow-up.

Для цитирования: Rawat Sanjib, Jaswal Vivek, Thingnam Shyam Kumar Singh, Singh Harkant, Mahajan Sachin, Kynta Reuben Lamiaki, Puri Goverdhan Dutt, Rohit Manoj Kumar. Short-term outcome of Polytetrafluoroethylene Membrane Valve versus Transannular Pericardial patch Reconstruction of Right Ventricular Outflow Tract in Tetralogy of Fallot: a Randomized Controlled Trial.. Brazilian journal of cardiovascular surgery. 2021. DOI: 10.21470/1678-9741-2020-0059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.