MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/01.ane.0000252461.97656.3e

Медицинская библиотека · Anesthesia and analgesia · 2007

A prospective comparison of vasopressor requirement and hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation versus singleton pregnancy.

Ngan Kee Warwick D, Khaw Kim S, Ng Floria F, Karmakar Manoj K, Critchley Lester A, Gin Tony

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

It is commonly taught that patients with multiple gestation pregnancy are prone to more severe hypotension during spinal and epidural anesthesia compared to those with singleton pregnancy. However, few quantitative data are available to support this claim. In this study, we prospectively compared vasopressor requirement and hemodynamic changes in patients with multiple gestation versus singleton pregnancy during spinal anesthesia for elective cesarean delivery.

METHODS

Forty parturients with multiple gestation and 60 singleton controls who had identical anesthetic management during spinal anesthesia for elective cesarean delivery were enrolled. After IV prehydration, patients received intrathecal bupivacaine-fentanyl and were tilted to the left. A metaraminol infusion was titrated with the target of maintaining systolic blood pressure at 90%-100% of baseline. Vasopressor dose, minimum and maximum values for systolic blood pressure and the incidences of hypotension, hypertension, and nausea/vomiting were compared.

RESULTS

All outcome variables were similar between groups. The total dose of metaraminol required until uterine incision was similar in multiple gestation pregnancy (median 2.9 [interquartile range 2.0-3.7] mg) when compared with singleton pregnancy (median 3.1 [interquartile range 2.3-3.9] mg, P = 0.25; median difference 0.30 mg, 95% confidence interval of difference -0.20 to 0.90 mg). Neonatal outcome was similar between groups.

CONCLUSION

Patients with multiple gestation pregnancy do not exhibit greater hemodynamic instability during spinal anesthesia for cesarean delivery compared to those with singleton pregnancy.

Для цитирования: Ngan Kee Warwick D, Khaw Kim S, Ng Floria F, Karmakar Manoj K, Critchley Lester A, Gin Tony. A prospective comparison of vasopressor requirement and hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation versus singleton pregnancy.. Anesthesia and analgesia. 2007. DOI: 10.1213/01.ane.0000252461.97656.3e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.