m+Medelevator.RU
← Поиск публикаций
Anesthesiology · 2011

Evaluation of a new routine diagnostic test for immunoglobulin E sensitization to neuromuscular blocking agents.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Laroche Dominique, Chollet-Martin Sylvie, Léturgie Pierre, Malzac Laure, Vergnaud Marie-Claude, Neukirch Catherine, Venemalm Lennart, Guéant Jean-Louis, Nicaise Roland Pascale

Аннотация

BACKGROUND: Neuromuscular blocking agents (NMBA) are responsible for most immediate hypersensitivity reactions during anesthesia, as a result of the presence of a quaternary ammonium ion. The aim of this study was to evaluate the diagnostic performance of a commercial immunoglobulin E (IgE) test (quaternary ammonium morphine [QAM]) for diagnosing sensitivity to NMBA.

METHODS: We tested 168 patients exposed to NMBAs during anesthesia. Of those patients, 54 had an uneventful procedure and 114 had immediate hypersensitivity reactions, and 57 patients had positive skin tests to the administered NMBA, whereas 57 had negative skin tests. Specific IgE concentrations determined with the QAM method based on a morphine solid phase were compared with those obtained with a recommended experimental method with a choline solid phase.

RESULTS: For the QAM test, a 0.35 kUA/l positivity cutoff was chosen from the receiver operating characteristics curve. QAM-specific IgE was found in 84.2% of skin test-positive reactors (80.7% with the recommended method; no significant difference), and binding was inhibited by the culprit NMBA in 80% of cases. The frequency of QAM-specific IgE positivity was significantly higher in skin test-negative reactors (24.6%) than in controls (9.3%), suggesting NMBA sensitivity.

CONCLUSION: Sensitivity of the QAM test (84.2%), together with its simplicity and suitability for routine laboratory use, makes it a valuable tool, in conjunction with skin tests, for diagnosing NMBA sensitivity in patients who react after NMBA injection. The QAM test is of particular interest when skin tests are not available or not reliable or give results poorly compatible with mediator release or clinical features.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты