MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-015-3784-2

Медицинская библиотека · European radiology · 2015

Mammographic density: Comparison of visual assessment with fully automatic calculation on a multivendor dataset.

Sacchetto Daniela, Morra Lia, Agliozzo Silvano, Bernardi Daniela, Björklund Tomas, Brancato Beniamino, Bravetti Patrizia, Carbonaro Luca A, Correale Loredana, Fantò Carmen, Favettini Elisabetta, Martincich Laura, Milanesio Luisella, Mombelloni Sara, Monetti Francesco, Morrone Doralba, Pellegrini Marco, Pesce Barbara, Petrillo Antonella, Saguatti Gianni, Stevanin Carmen, Trimboli Rubina M, Tuttobene Paola, Valentini Marvi, Marra Vincenzo, Frigerio Alfonso, Bert Alberto, Sardanelli Francesco

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset.

METHODS

Twenty-one radiologists assessed 613 screening/diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (κ) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification.

RESULTS

While the agreement of individual radiologists with the PMR ranged from κ = 0.483 to κ = 0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (κ = 0.620, standard deviation [SD] = 0.140), individual versus PMR (κ = 0.736, SD = 0.117), and individual versus ABDE (κ = 0.674, SD = 0.095). Agreement between ABDE and PMR was almost perfect (κ = 0.831).

CONCLUSIONS

The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation.

KEY POINTS: Individual BD assessment differs from PMR with κ as low as 0.483. An ABDE correctly classified 92 % of mammograms with almost perfect agreement (κ = 0.831). An ABDE can be a valid alternative to subjective BD assessment.

Для цитирования: Sacchetto Daniela, Morra Lia, Agliozzo Silvano, Bernardi Daniela, Björklund Tomas, Brancato Beniamino, Bravetti Patrizia, Carbonaro Luca A, Correale Loredana, Fantò Carmen, Favettini Elisabetta, Martincich Laura, Milanesio Luisella, Mombelloni Sara, Monetti Francesco, Morrone Doralba, Pellegrini Marco, Pesce Barbara, Petrillo Antonella, Saguatti Gianni, Stevanin Carmen, Trimboli Rubina M, Tuttobene Paola, Valentini Marvi, Marra Vincenzo, Frigerio Alfonso, Bert Alberto, Sardanelli Francesco. Mammographic density: Comparison of visual assessment with fully automatic calculation on a multivendor dataset.. European radiology. 2015. DOI: 10.1007/s00330-015-3784-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.