Impact of bronchoscopic lung volume reduction with endobronchial valves on dynamic hyperinflation: Results from the PIERCE study.

Fumat Romane, Dupuis Marion, Mallah Siham, Heluain Valentin, Favard Florent, Simonneau Yannick, Dusselier Matthieu, Barthes Romain, Pontier Sandrine, Collot Samia, Plat Gavin, Egenod Thomas, Guibert Nicolas

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Dynamic hyperinflation (DH) is a major marker of exertional dyspnoea in severe emphysema. We hypothesized that bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) decreases DH.

METHODS

In this prospective bi-centre study from both Toulouse and Limoges Hospitals, we assessed DH during an incremental cycle ergometry before and 3 months after EBVs treatment. The primary objective was to observe the change in inspiratory capacity (IC) at isotime. Target lobe volume reduction (TLVR) and changes in residual volume (RV), forced expiratory volume in one-second (FEV1 ), mMRC, 6 minutes walking distance (6MWD), BODE and other dynamic measures like tele-expiratory volume (EELV) were also analysed.

RESULTS

Thirty-nine patients were included, of whom thirty-eight presented DH. IC and EELV at isotime significantly improved (+214 mL, p = 0.004; -713 mL, p ˂ 0.001, respectively). Mean changes were +177 mL for FEV1 (+19%, p < 0.001), -600 mL for RV (p < 0.0001), +33 m for 6MWD (p < 0.0001), respectively. Patients who responded on RV (>430 mL decrease) and FEV1 (>12% gain) had better improvements compared to non-responders (+368 mL vs. +2 mL; +398 mL vs. -40 mL IC isotime, respectively). On the opposite, in patients who responded on DH (>200 mL IC isotime increase), changes in TLV (-1216 mL vs. -576 mL), FEV1 (+261 mL vs. +101 mL), FVC (+496 mL vs. +128 mL) and RV (-805 mL vs. -418 mL) were greater compared to non-responders.

CONCLUSIONS

DH decreases after EBVs treatment, and this improvement is correlated with static changes.

Для цитирования: Fumat Romane, Dupuis Marion, Mallah Siham, Heluain Valentin, Favard Florent, Simonneau Yannick, Dusselier Matthieu, Barthes Romain, Pontier Sandrine, Collot Samia, Plat Gavin, Egenod Thomas, Guibert Nicolas. Impact of bronchoscopic lung volume reduction with endobronchial valves on dynamic hyperinflation: Results from the PIERCE study.. Respirology (Carlton, Vic.). 2023. DOI: 10.1111/resp.14488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.