DOI 10.1016/j.jenvman.2023.117463
Multi-objective optimization of hydrant flushing in a water distribution system using a fast hybrid technique.
Аннотация
As a critical element in preserving the health of urban populations, water distribution systems (WDSs) must be ready to implement emergency plans when catastrophic events such as contamination events occur. A risk-based simulation-optimization framework (EPANET-NSGA-III) combined with a decision support model (GMCR) is proposed in this study to determine optimal locations for contaminant flushing hydrants under an array of potentially hazardous scenarios. Risk-based analysis using Conditional Value-at-Risk (CVaR)-based objectives can address uncertainties regarding the mode of WDS contamination, thereby providing a robust plan to minimize the associated risks at a 95% confidence level. Conflict modeling by GMCR achieved an optimal compromise solution within the Pareto front by identifying a final stable consensus among the decision-makers involved. A novel hybrid contamination event grouping-parallel water quality simulation technique was incorporated into the integrated model to reduce model runtime, the main deterrent in optimization-based methods. The nearly 80% reduction in model runtime made the proposed model a viable solution for online simulation-optimization problems. The framework's capacity to address real-world problems was evaluated for the WDS operating in Lamerd, a city in Fars Province, Iran. Results showed that the proposed framework was capable of highlighting a single flushing strategy, which not only optimally reduced risks associated with contamination events, but provided acceptable coverage against such threats, flushing 35-61.3% of input contamination mass on average, and reducing average time-to-return to normal conditions by 14.4-60.2%, while employing less than half of the initial potential hydrants.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.