Ho Jacky Y K, Kim Chong Hoon, Chow Simon C Y, Kwok Micky W T, Lee Ha, Kim Tae-Hoon, Fujikawa Takuya, Wong Randolph H L, Song Suk-Won

Аннотация

BACKGROUND: Aortic arch pathology often requires staged segmental repairs. Total aortic arch replacement with frozen elephant trunk (FET) offers surgical options for these pathologies. The Jotec E-vita Open NEO™ branched prosthesis was introduced in 2020; we sought to share our initial experience focusing on the prosthesis selection strategies, surgical techniques, anastomosis-bleeding and graft-oozing control methods, and early clinical outcomes from two Asian centers.

METHODS: We performed a retrospective cohort study in patients with aortic arch pathologies who underwent total arch replacement using the FET procedure with Jotec E-vita Open NEO™ branched prosthesis from two Asian centers between October 2020 and August 2021. The primary outcome was overall 30-day mortality, and the secondary outcomes were operative complications.

RESULTS: Twenty-five consecutive patients underwent total arch replacement with FET with the novel hybrid prosthesis. Overall 30-day mortality from both centers was 0%. Overall mean operative, cardiopulmonary bypass, hypothermic circulatory arrest, and selective antegrade cerebral perfusion times were 353.4±80.5, 183.2±39.6, 57.2±14.7, and 138.2±28.6 minutes, respectively. No patient developed stroke. Permanent spinal cord injury (SCI) was recorded in one patient (4%) and one (4%) had transient lower limb weakness that resolved after spinal drainage. There was no requirement of re-sternotomy for hemostasis.

CONCLUSIONS: We reported a multicenter Asian case series with the novel FET hybrid prosthesis demonstrating the feasibility and safety of promising initial clinical outcomes. The technique of circumferential reinforcement of vascular anastomosis for hemostasis may be one of the methods for lowering the rates of re-sternotomy for hemostasis, and proper surgical or transfusion strategies would overcome the excessive oozing of the prosthesis. Long-term follow-up is required for further evaluation of aortic pathology progression and device-related outcomes.