MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2020.06.008

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2020

Duct stenting versus modified Blalock-Taussig shunt in neonates and infants with duct-dependent pulmonary blood flow: A systematic review and meta-analysis.

Alsagheir Ali, Koziarz Alex, Makhdoum Ahmad, Contreras Juan, Alraddadi Hatim, Abdalla Tasnim, Benson Lee, Chaturvedi Rajiv R, Honjo Osami

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

The aim of this systematic review and meta-analysis is to evaluate whether duct stenting is associated with better survival and other clinical outcomes compared with the modified Blalock-Taussig shunt in infants with duct-dependent pulmonary flow.

METHODS

A systematic search of the Medline, Embase, and Cochrane databases was performed by 4 independent reviewers from inception to March 2019. Meta-analysis was performed using the DerSimonian and Laird method with inverse-variance weighting. The quality of evidence was summarized using the Grading of Recommendations, Assessment, Development, and Evaluation framework.

RESULTS

Six comparative observational studies were included, of which 3 were rated low risk of bias. There was no difference in 30-day mortality between the Blalock-Taussig shunt and duct stenting groups (risk ratio, 1.02; 95% confidence interval, 0.46-2.27; P = .96; I2 = 0%). However, there was benefit in favor of duct stenting for medium-term mortality (risk ratio, 0.63; 95% confidence interval, 0.40-0.99; P = .05; I2 = 0%). Duct stenting demonstrated a reduced risk for procedural complications compared with the Blalock-Taussig shunt (risk ratio, 0.50; 95% confidence interval, 0.31-0.81; P = .005; I2 = 0%). However, there was an increased risk for unplanned reintervention for duct stenting (risk ratio, 1.77; 95% confidence interval, 1.39-2.26; P < .00001; I2 = 10%). Duct stenting demonstrated shorter mean intensive care unit length of stay (mean difference, -4.69 days; 95% confidence interval, -7.30 to -2.07; P = .0004; I2 = 80%), as well as shorter hospital length of stay (mean difference, -5.78 days; 95% confidence interval, -9.27 to -2.28; P = .0009, I2 = 75%). The overall quality of evidence was rated low using the Grading of Recommendations, Assessment, Development, and Evaluation framework.

CONCLUSIONS

Duct stenting demonstrated comparable early mortality, lower medium-term mortality, lower risk of procedural complications, and higher risk of reintervention compared with the Blalock-Taussig shunt.

Для цитирования: Alsagheir Ali, Koziarz Alex, Makhdoum Ahmad, Contreras Juan, Alraddadi Hatim, Abdalla Tasnim, Benson Lee, Chaturvedi Rajiv R, Honjo Osami. Duct stenting versus modified Blalock-Taussig shunt in neonates and infants with duct-dependent pulmonary blood flow: A systematic review and meta-analysis.. The Journal of thoracic and cardiovascular surgery. 2020. DOI: 10.1016/j.jtcvs.2020.06.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.