MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s2589-7500(23)00020-1

Медицинская библиотека · The Lancet. Digital health · 2023

Development and validation of an electronic daily control score for asthma (e-DASTHMA): a real-world direct patient data study.

Sousa-Pinto Bernardo, Jácome Cristina, Pereira Ana Margarida, Regateiro Frederico S, Almeida Rute, Czarlewski Wienczyslawa, Kulus Marek, Shamji Mohamed H, Boulet Louis-Philippe, Bonini Matteo, Brussino Luisa, Canonica G Walter, Cruz Alvaro A, Gemicioglu Bilun, Haahtela Tari, Kupczyk Maciej, Kvedariene Violeta, Larenas-Linnemann Desirée, Louis Renaud, Niedoszytko Marek, Pham-Thi Nhân, Puggioni Francesca, Romantowski Jan, Sastre Joaquin, Scichilone Nicola, Taborda-Barata Luis, Ventura Maria Teresa, Vieira Rafael José, Agache Ioana, Bedbrook Anna, Bergmann Karl C, Amaral Rita, Azevedo Luís Filipe, Bosnic-Anticevich Sinthia, Brusselle Guy, Buhl Roland, Cecchi Lorenzo, Charpin Denis, Loureiro Claudia Chaves, de Blay Frédéric, Del Giacco Stefano, Devillier Philippe, Jassem Ewa, Joos Guy, Jutel Marek, Klimek Ludger, Kuna Piotr, Laune Daniel, Luna Pech Jorge, Makela Mika, Morais-Almeida Mario, Nadif Rachel, Neffen Hugo E, Ohta Ken, Papadopoulos Nikolaos G, Papi Alberto, Pétré Benoit, Pfaar Oliver, Yeverino Daniela Rivero, Cordeiro Carlos Robalo, Roche Nicolas, Sá-Sousa Ana, Samolinski Boleslaw, Sheikh Aziz, Ulrik Charlotte Suppli, Usmani Omar S, Valiulis Arunas, Vandenplas Olivier, Vieira-Marques Pedro, Yorgancioglu Arzu, Zuberbier Torsten, Anto Josep M, Fonseca João A, Bousquet Jean

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Validated questionnaires are used to assess asthma control over the past 1-4 weeks from reporting. However, they do not adequately capture asthma control in patients with fluctuating symptoms. Using the Mobile Airways Sentinel Network for airway diseases (MASK-air) app, we developed and validated an electronic daily asthma control score (e-DASTHMA).

METHODS

We used MASK-air data (freely available to users in 27 countries) to develop and assess different daily control scores for asthma. Data-driven control scores were developed based on asthma symptoms reported by a visual analogue scale (VAS) and self-reported asthma medication use. We included the daily monitoring data from all MASK-air users aged 16-90 years (or older than 13 years to 90 years in countries with a lower age of digital consent) who had used the app in at least 3 different calendar months and had reported at least 1 day of asthma medication use. For each score, we assessed construct validity, test-retest reliability, responsiveness, and accuracy. We used VASs on dyspnoea and work disturbance, EQ-5D-VAS, Control of Allergic Rhinitis and Asthma Test (CARAT), CARAT asthma, and Work Productivity and Activity Impairment: Allergy Specific (WPAI:AS) questionnaires as comparators. We performed an internal validation using MASK-air data from Jan 1 to Oct 12, 2022, and an external validation using a cohort of patients with physician-diagnosed asthma (the INSPIRERS cohort) who had had their diagnosis and control (Global Initiative for Asthma [GINA] classification) of asthma ascertained by a physician.

FINDINGS: We studied 135 635 days of MASK-air data from 1662 users from May 21, 2015, to Dec 31, 2021. The scores were strongly correlated with VAS dyspnoea (Spearman correlation coefficient range 0·68-0·82) and moderately correlated with work comparators and quality-of-life-related comparators (for WPAI:AS work, we observed Spearman correlation coefficients of 0·59-0·68). They also displayed high test-retest reliability (intraclass correlation coefficients range 0·79-0·95) and moderate-to-high responsiveness (correlation coefficient range 0·69-0·79; effect size measures range 0·57-0·99 in the comparison with VAS dyspnoea). The best-performing score displayed a strong correlation with the effect of asthma on work and school activities in the INSPIRERS cohort (Spearman correlation coefficients 0·70; 95% CI 0·61-0·78) and good accuracy for the identification of patients with uncontrolled or partly controlled asthma according to GINA (area under the receiver operating curve 0·73; 95% CI 0·68-0·78).

INTERPRETATION: e-DASTHMA is a good tool for the daily assessment of asthma control. This tool can be used as an endpoint in clinical trials as well as in clinical practice to assess fluctuations in asthma control and guide treatment optimisation.

FUNDING: None.

Для цитирования: Sousa-Pinto Bernardo, Jácome Cristina, Pereira Ana Margarida, Regateiro Frederico S, Almeida Rute, Czarlewski Wienczyslawa, Kulus Marek, Shamji Mohamed H, Boulet Louis-Philippe, Bonini Matteo, Brussino Luisa, Canonica G Walter, Cruz Alvaro A, Gemicioglu Bilun, Haahtela Tari, Kupczyk Maciej, Kvedariene Violeta, Larenas-Linnemann Desirée, Louis Renaud, Niedoszytko Marek, Pham-Thi Nhân, Puggioni Francesca, Romantowski Jan, Sastre Joaquin, Scichilone Nicola, Taborda-Barata Luis, Ventura Maria Teresa, Vieira Rafael José, Agache Ioana, Bedbrook Anna, Bergmann Karl C, Amaral Rita, Azevedo Luís Filipe, Bosnic-Anticevich Sinthia, Brusselle Guy, Buhl Roland, Cecchi Lorenzo, Charpin Denis, Loureiro Claudia Chaves, de Blay Frédéric, Del Giacco Stefano, Devillier Philippe, Jassem Ewa, Joos Guy, Jutel Marek, Klimek Ludger, Kuna Piotr, Laune Daniel, Luna Pech Jorge, Makela Mika, Morais-Almeida Mario, Nadif Rachel, Neffen Hugo E, Ohta Ken, Papadopoulos Nikolaos G, Papi Alberto, Pétré Benoit, Pfaar Oliver, Yeverino Daniela Rivero, Cordeiro Carlos Robalo, Roche Nicolas, Sá-Sousa Ana, Samolinski Boleslaw, Sheikh Aziz, Ulrik Charlotte Suppli, Usmani Omar S, Valiulis Arunas, Vandenplas Olivier, Vieira-Marques Pedro, Yorgancioglu Arzu, Zuberbier Torsten, Anto Josep M, Fonseca João A, Bousquet Jean. Development and validation of an electronic daily control score for asthma (e-DASTHMA): a real-world direct patient data study.. The Lancet. Digital health. 2023. DOI: 10.1016/s2589-7500(23)00020-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.