Effect of High-Flow Nasal Cannula Flow on Intrapharyngeal Pressure During Fiberoptic Bronchoscopy Under Deep Sedation.

Li Jie, Liu Bin, Gao Lin, Li Na, Yuan Xiao-Zhong, Zhu Yi-Xuan, Deng Kang

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The flow reaching the vocal folds may be lower than that at the output of high-flow nasal cannula (HFNC) system. This could be due to upper-respiratory obstruction, oxygen leakage, or other factors. The objective of this study was to observe the effect of flow through a nasopharyngeal airway on intrapharyngeal pressure (IPP) in subjects undergoing fiberoptic bronchoscopy (FOB).

METHODS

Patients scheduled for FOB were invited to participate. Measurements were performed at flows of 0-60 L/min; the subjects wore WN-N95 folding medical protective masks (N95) and either underwent FOB or not. IPP at each flow was recorded following 15 s of ventilation, and the cross-sectional area (CSA) of the gastric sinus was measured before and after FOB. Hypoxemia, reflux aspiration, and other pertinent events were recorded.

RESULTS

Sixty subjects undergoing FOB at the Affiliated Hospital of Jiaxing University participated in this trial from October 2022-September 2023. IPP increased significantly with an increase in flow and also increased after placing the N95 mask with the same flow (P < .001). When results from before to after FOB were compared, the difference in CSA was statistically significant 263.6 (220.7-300.5) mm2 vs 305.5 (275.4-329.5) mm2, P < .001, but the difference in the risk of reflux aspiration was not statistically significant (0% vs 6.7%, P = .13). Complication rates during treatment were 8.3% for hypoxemia, 0% for reflux aspiration, 1.7% for hypertension, 1.7% for hypotension, 6.7% for tachycardia, 5% for bradycardia, and 10% for postoperative nausea and vomiting.

CONCLUSIONS

HFNC can provide effective oxygen therapy for people undergoing FOB, and increases in IPP with flow in the range of 0-60 L/min may not increase the risk of reflux aspiration.

Для цитирования: Li Jie, Liu Bin, Gao Lin, Li Na, Yuan Xiao-Zhong, Zhu Yi-Xuan, Deng Kang. Effect of High-Flow Nasal Cannula Flow on Intrapharyngeal Pressure During Fiberoptic Bronchoscopy Under Deep Sedation.. Respiratory care. 2024. DOI: 10.4187/respcare.11697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.