MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199241246135

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024

Multicenter US clinical experience with the Scepter Mini balloon catheter.

Salem Mohamed M, Kelmer Paz, Sioutas Georgios S, Ostmeier Sophie, Hoang Alex, Cortez Gustavo, El Naamani Kareem, Abbas Rawad, Hanel Ricardo, Tanweer Omar, Srinivasan Visish M, Jabbour Pascal, Kan Peter, Jankowitz Brian T, Heit Jeremy J, Burkhardt Jan-Karl

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

IntroductionDistal navigability and imprecise delivery of embolic agents are two limitations encountered during liquid embolization of cerebrospinal lesions. The dual-lumen Scepter Mini balloon (SMB) microcatheter was introduced to overcome these conventional microcatheters' limitations with few small single-center reports suggesting favorable results.MethodsA series of consecutive patients undergoing SMB-assisted endovascular embolization were extracted from prospectively maintained registries in seven North-American centers (November 2019 to September 2022).ResultsFifty-four patients undergoing 55 embolization procedures utilizing SMB were included (median age 58.5; 48.1% females). Cranial dural arteriovenous fistula embolization was the most common indication (54.5%) followed by cranial arteriovenous malformation (27.3%). Staged/pre-operative embolization was done in 36.4% of cases; and 83.6% of procedures using Onyx-18. Most procedures utilized a transarterial approach (89.1%), and SMB-induced arterial-flow arrest concurrently with transvenous embolization was used in 10.9% of procedures. Femoral access/triaxial setups were utilized in the majority of procedures (65.5% and 60%, respectively). The median vessel diameter where the balloon was inflated of 1.8 mm, with a median of 1.5 cc of injected embolic material per procedure. Technical failures occurred in 5.5% of cases requiring aborting/replacement with other devices without clinical sequelae in any of the patients, with SMB-related procedural complications of 3.6% without clinical sequelae. Radiographic imaging follow-up was available in 76.9% of the patients (median follow-up 3.8 months), with complete occlusion (100%) or >50% occlusion in 92.5% of the cases, and unplanned retreatments in 1.8%.ConclusionThe SMB microcatheter is a useful new adjunctive device for balloon-assisted embolization of cerebrospinal lesions with a high technical success rate, favorable outcomes, and a reasonable safety profile.

Для цитирования: Salem Mohamed M, Kelmer Paz, Sioutas Georgios S, Ostmeier Sophie, Hoang Alex, Cortez Gustavo, El Naamani Kareem, Abbas Rawad, Hanel Ricardo, Tanweer Omar, Srinivasan Visish M, Jabbour Pascal, Kan Peter, Jankowitz Brian T, Heit Jeremy J, Burkhardt Jan-Karl. Multicenter US clinical experience with the Scepter Mini balloon catheter.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2024. DOI: 10.1177/15910199241246135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.