DOI 10.1371/journal.pone.0340206

Медицинская библиотека · PloS one · 2026

Reliability of pressure-volume loop parameters derived from transthoracic echocardiography in patients undergoing hemodialysis.

Galiyeva Dinara, Khamitova Zaukiya, Zhankorazova Aizhan, Nurkesh Ayan, Jumadilova Dinara, Toktarbay Bauyrzhan, Mukarov Murat, Kokoskho Alexey, Gaipov Abduzhappar, Salustri Alessandro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The pressure-volume (PV) relationship remains a key tool for assessing cardiac function. PV loop derived parameters, including end-systolic elastance (Ees), effective arterial elastance (Ea), ventriculo-arterial coupling (VAC), stroke work (SW), pressure-volume area (PVA), and work efficiency (WE), are valuable tools, but reproducibility data are scarce.

OBJECTIVE

To evaluate the inter- and intra-observer variability of PV loop parameters derived from transthoracic echocardiography images in patients undergoing hemodialysis.

METHODS

Twenty-five adult patients with end-stage renal disease undergoing maintenance hemodialysis were randomly selected. PV loops were reconstructed using Q-Strain software (version 1.3.0.79, Medis, Leiden, the Netherlands), and parameters including Ees, Ea, VAC, SW, PVA, and WE were calculated. Two experienced readers performed measurements for inter-observer analysis; one reader repeated measurements one week apart for intra-observer analysis. Reliability was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots.

RESULTS

Inter-observer agreement was excellent for SW 0.96 (0.91-0.98) and PVA 0.95 (0.87-0.98), good for Ees 0.90 (0.77-0.96) and Ea 0.79 (0.49-0.91), and moderate for VAC 0.68 (0.23-0.85) and WE 0.72 (0.28-0.79). Intra-observer agreement was excellent for Ees 0.96 (0.90-0.98), Ea 0.98 (0.94-0.99), SW 0.98 (0.96-0.99) and PVA 0.98 (0.96-0.99), and good for VAC 0.78 (0.51-0.91) and WE 0.85 (0.65-0.94). Bland-Altman analysis showed minimal bias for Ees, SW and PVA, whereas Ea, VAC and WE exhibited proportional bias.

CONCLUSIONS

PV loop-derived parameters obtained via transthoracic echocardiography demonstrate good-to-excellent reproducibility, particularly for Ees, Ea, SW and PVA. VAC and WE show moderate variability, suggesting careful interpretation of these parameters in clinical and research settings.

Для цитирования: Galiyeva Dinara, Khamitova Zaukiya, Zhankorazova Aizhan, Nurkesh Ayan, Jumadilova Dinara, Toktarbay Bauyrzhan, Mukarov Murat, Kokoskho Alexey, Gaipov Abduzhappar, Salustri Alessandro. Reliability of pressure-volume loop parameters derived from transthoracic echocardiography in patients undergoing hemodialysis.. PloS one. 2026. DOI: 10.1371/journal.pone.0340206.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.