A direct metal laser sintering (DMLS) root analogue implant placed in the anterior maxilla. Case report.
Аннотация
BACKGROUND
Modern cone beam computed tomography (CBCT) acquisition and three-dimensional (3D) image processing, combined with direct metal laser sintering (DMLS), allows custom-made, root-analogue implants (RAIs).
PURPOSE: To demonstrate how DMLS permits customized titanium RAI production, with immediate insertion and restoration in a fresh extraction socket of the anterior maxilla.
MATERIALS AND
METHODS
A titanium RAI perfect copy of the radicular unit needed for replacement was created by customized DMLS, and inserted into a fresh extraction socket of the esthetic area of the anterior maxilla.
RESULTS
Follow-up after 1 year: the DMLS RAI implant showed a satisfactory functional and esthetic integration, with no bone resorption or soft tissue recessions.
CONCLUSIONS
The production of customized DMLS RAIs opens new interesting perspectives for immediate implantation.
KEY WORDS: Direct metal laser sintering, Root analogue implant.