BACKGROUND

To develop a more accurate methodology for diagnosing active tuberculous pleurisy, as well as peritonitis and pericardits of tuberculous origin, we established an antigen-specific interferon gamma (IFN-gamma)-based assay that uses cavity fluid specimens.

METHODS

Over a 19-month period, 155 consecutive, nonselected patients with any cavity effusion were evaluated. Study subjects were 28 patients with bacteriologically confirmed active tuberculous serositis and 47 patients with definitive nontuberculous etiology. Culture was performed for 18 h with fluid mononuclear cells in the supernatant of the effusion together with saline or Mycobacterium tuberculosis-specific antigenic peptides, early secretory antigenic target 6 and culture filtrate protein 10. IFN-gamma concentrations in the culture supernatants were measured.

RESULTS

In patients with active tuberculous serositis, antigen-specific IFN-gamma responses of cavity fluid samples were significantly higher than those of nontuberculous effusion samples. Area under the receiver operating characteristic (AUROC) curve was significantly greater for cavity fluid IFN-gamma response (AUROC curve, 0.996) than for cavity fluid adenosine deaminase and whole-blood IFN-gamma responses (AUROC curve, 0.882 and 0.719, respectively; P = .037 and P < .001, respectively). Although the AUROC curve was greater for cavity fluid IFN-gamma response than for background cavity fluid IFN-gamma level (AUROC curve, 0.975), the AUROC curves were not statistically significantly different (P = .74). However, multivariate logistic regression analysis revealed that cavity fluid IFN-gamma responses were significantly associated with the diagnosis, even after adjustment for background IFN-gamma level (adjusted odds ratio, 1.21; 95% confidence interval, 1.03-1.42; P < .001).

CONCLUSIONS

The cavity fluid IFN-gamma assay could be a method for accurately and promptly diagnosing active tuberculous serositis.

Для цитирования: Ariga Haruyuki, Kawabe Yoshiko, Nagai Hideaki, Kurashima Atsuyuki, Masuda Kimihiko, Matsui Hirotoshi, Tamura Atsuhisa, Nagayama Naohiro, Akagawa Shinobu, Machida Kazuko, Hebisawa Akira, Nakajima Yutsuki, Yotsumoto Hideki, Mori Toru. Diagnosis of active tuberculous serositis by antigen-specific interferon-gamma response of cavity fluid cells.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2007. DOI: 10.1086/523591.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.