MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1748-717x-9-104

Медицинская библиотека · Radiation oncology (London, England) · 2014

V30 as a predictor for radiation-induced hypothyroidism: a dosimetric analysis in patients who received radiotherapy to the neck.

Akgun Zuleyha, Atasoy Beste M, Ozen Zeynep, Yavuz Dilek, Gulluoglu Bahadir, Sengoz Meric, Abacioglu Ufuk

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The purpose of this study is to evaluate the possible predictors of thyroid disorders after neck radiotherapy, with a focus on radiation dose-volume factors.

METHODS

Thyroid function was measured in 100 patients who had received radiotherapy to the neck, including the thyroid. All radiation-induced thyroid dysfunctions were determined with an endpoint of abnormal thyroid stimulating hormone (TSH), free triiodothyronine (fT3) and thyroxine (fT4) and thyroid peroxidase antibodies and (TPA). The total volume of the thyroid, mean radiation dose to the thyroid (Dmean) and thyroid volume percentage that received radiation doses of 10-50 Gy (V10-V50) were calculated in all patients. The evaluated risk factors for thyroid dysfunction included dose-volume parameters, sex, age, previous surgery, chemotherapy and comorbidity.

RESULTS

There were 52 patients with hypothyroidism and V30 (p = 0.03), thyroid volume (p = 0.01) and Dmean (p = 0.03) appeared to be correlated with hypothyroidism in univariate analysis. However, there was not association found in multivariate analysis for these factors.

CONCLUSIONS

Thyroid disorders after radiation therapy to the neck still represent a clinically underestimated problem. V30 may be a useful tool for evaluating the risk of hypothyroidism when determining an individual patient's treatment.

Для цитирования: Akgun Zuleyha, Atasoy Beste M, Ozen Zeynep, Yavuz Dilek, Gulluoglu Bahadir, Sengoz Meric, Abacioglu Ufuk. V30 as a predictor for radiation-induced hypothyroidism: a dosimetric analysis in patients who received radiotherapy to the neck.. Radiation oncology (London, England). 2014. DOI: 10.1186/1748-717x-9-104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.