Heymann Jonas J, Pineda Cristiana M, Booth Christine N, Jenkins Elizabeth, Menke Joshua R, Monaco Sara E, Nayar Ritu, Nishino Michiya, Roy-Chowdhuri Sinchita, Ruiz-Cordero Roberto, Russell Donna K, Saqi Anjali, Sundling Kaitlin E, Thrall Michael J, Torous Vanda F, VandenBussche Christopher J, VanderLaan Paul A, Zhang M Lisa, Siddiqui Momin T

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Ancillary testing on cytopathology and other small biopsy specimens is crucial for diagnosis and provides critical information to clinicians. Testing is dependent on preanalytic factors and would benefit from standardization of specimen collection protocols across laboratories. To assess institutional practices and areas of need for evidence-based standards, we surveyed current practices across cytopathology laboratories.

MATERIALS AND

METHODS

A twelve-question electronic survey was distributed to American Society of Cytopathology (ASC) members through email, social media, and the ASC from January 8, 2024 to March 1, 2024. Survey responses were tabulated.

RESULTS

Of 294 respondents, 257 (87%) completed at least 10/12 questions. Formalin-fixed, paraffin-embedded cell blocks (CBs) are utilized for immunohistochemistry, molecular testing, and in situ hybridization by 89%, 84%, and 71% of respondents, respectively. For fine needle aspirations, no collection medium is utilized by a majority of respondents. In contrast, 61% utilize no collection medium for fluids; 64% predominantly utilize liquid-based preservatives for other exfoliative specimens. For CB preparation, 58% of respondents use coagulating agent; 67% use no fixative before formalin. The two most significant factors limiting clinical utility of ancillary testing in cytology specimens are low cellularity and lack of validation (49% and 23% of respondents, respectively).

CONCLUSIONS

There is wide variation in current practices among laboratories, reflecting lack of consensus. Although laboratories utilize different collection media for different specimen types, for CB utilization, current survey results are similar to those reported previously. ASC has convened a task force to facilitate specimen standardization and minimize variability among preanalytic factors.

Для цитирования: Heymann Jonas J, Pineda Cristiana M, Booth Christine N, Jenkins Elizabeth, Menke Joshua R, Monaco Sara E, Nayar Ritu, Nishino Michiya, Roy-Chowdhuri Sinchita, Ruiz-Cordero Roberto, Russell Donna K, Saqi Anjali, Sundling Kaitlin E, Thrall Michael J, Torous Vanda F, VandenBussche Christopher J, VanderLaan Paul A, Zhang M Lisa, Siddiqui Momin T. Tools, techniques, and challenges in preparing cytology specimens for ancillary studies: results of the ASC Optimizing Cytology and Small Biopsy Specimen Processing for Ancillary Studies task force survey.. Journal of the American Society of Cytopathology. 2024. DOI: 10.1016/j.jasc.2024.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.