MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejmp.2025.104990

Медицинская библиотека · Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025

Fully automated image quality assessment based on deep learning for carotid computed tomography angiography: A multicenter study.

Fu Wanyun, Ma Zhangman, Yang Zhiwen, Yu Shufeng, Zhang Yongsheng, Zhang Xinsheng, Mei Bozhe, Meng Yu, Ma Chune, Gong Xiangyang

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To develop and evaluate the performance of fully automated model based on deep learning and multiple logistics regression algorithm for image quality assessment (IQA) of carotid computed tomography angiography (CTA) images.

METHODS

This study retrospectively collected 840 carotid CTA images from four tertiary hospitals. Three radiologists independently assessed the image quality using a 3-point Likert scale, based on the degree of noise, vessel enhancement, arterial vessel contrast, vessel edge sharpness, and overall diagnostic acceptability. An automated assessment model was developed using a training dataset consisting of 600 carotid CTA images. The assessment steps included: (i) selection of objective representative slices; (ii) use of 3D Res U-net approach to extract objective indices from the representative slices and (iii) use of single objective index and multiple indices combinedly to develop logistic regression models for IQA. In the internal and external test datasets (n = 240), the performance of models was evaluated using sensitivity, specificity, precision, F-score, accuracy, the area under the receiver operating characteristic curve (AUC), and the IQA results of models was compared with radiologists' consensus.

RESULTS

The representative slices were determined based on the same length model. The performance of multi-index model was excellent in internal and external test datasets with AUCs of 0.98 and 0.97. And the consistency between model and radiologists achieved 91.8% (95% CI: 87.0-96.5) and 92.6% (95 % CI: 86.9-98.4) in internal and external test datasets respectively.

CONCLUSION

The fully automated multi-index model showed equivalent performance to the subjective perceptions of radiologists with greater efficiency for IQA.

Для цитирования: Fu Wanyun, Ma Zhangman, Yang Zhiwen, Yu Shufeng, Zhang Yongsheng, Zhang Xinsheng, Mei Bozhe, Meng Yu, Ma Chune, Gong Xiangyang. Fully automated image quality assessment based on deep learning for carotid computed tomography angiography: A multicenter study.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2025. DOI: 10.1016/j.ejmp.2025.104990.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.